3516 Diesel Generator Set
At a Glance
Standby Rating
1750 ekW
|
Prime Power Rating
1600 ekW
|
Emissions/Fuel Strategy
Low Fuel, Low Emissions
|
Voltage
380 to 13800 Volts
|
Request a Quote
Overview
The 3516 generator set has been developed for a wide range of applications, from emergency standby installations such as healthcare and datacenters to continuously powering remote installations. The packages can be optimized for performance that matters to you with either low emissions or low fuel consumption versions available. Backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty, Cat generator sets will provide the reliability and durability you expect.
Generator Set Specifications
+
-
Standby Rating |
1750 ekW |
Prime Power Rating |
1600 ekW |
Emissions/Fuel Strategy |
Low Fuel, Low Emissions |
Voltage |
380 to 13800 Volts |
Frequency |
60 Hz |
Speed |
1800 rpm |
Duty Cycle |
Standby, Mission Critical, Prime, Continuous |
Maximum Rating |
1750 ekW |
Minimum Rating |
1450 ekW |
Engine Specifications
+
-
Engine Model |
3516 TA, V-16, 4-Stroke Water-Cooled Diesel |
Bore |
6.69in |
Stroke |
7.48in |
Displacement |
4210.64in³ |
Compression Ratio |
13.0:1 |
Aspiration |
TA |
Fuel System |
Mechanical unit injection |
Governor Type |
Woodward |
Generator Set Dimensions
+
-
Length - Maximum |
247in |
Width - Maximum |
90in |
Height - Maximum |
94.9in |
Dry Weight - Genset (maximum) |
28840lb |
Standard Equipment:
Air Inlet System
+
-
-
Air cleaner; single element canister type
Control Panels
+
-
-
Accessory module data link
-
Low coolant level
-
Environmental sealed front face
-
EMCP 4.2B
-
6 Customer programmable digital inputs
-
Communications:
-
Load histogram feature
-
Overspeed
-
Alarm acknowledge
-
kW-hr (total)
-
24 Volt DC operation
-
Over/under voltage (27/59)
-
1 programmable relay outputs (Form C)
-
kVAr-hr (total)
-
Emergency stop pushbutton
-
PLC functionality
-
Speed adjust
-
Lamp test
-
Auto/start/stop control
-
Over/under frequency (81 o/u)
-
Generator phase sequence
-
Revers Power (kW) (32)
-
Oil pressure (psi, kPa or bar
-
Coolant temperature
-
RPM
-
Overcurrent (50/51)
-
IVR includes reactive droop capability, 3-phase voltage sensing,
KVAR / PF modes, RFI suppression, min / max exciter.
Limiter and exciter diode monitor
-
Controls:
-
Number of I/O varies on options selected
-
Power factor (per phase & average)
-
0 True RMS AC metering, 3-phase, +/-2% accuracy
-
kVA (per phase, average & percent)
-
Serial annunciator module data link
-
Customizable screens
-
Generator mounted - rear facing
-
kW (per phase, average & percent)
-
Text alarm/event descriptions
-
DC volts
-
Low oil pressure
-
Controls: Speed adjust - Auto/start/stop control - Engine cool-down timer - Engine cycle crank - Alarm acknowledge - Lamp test - Load histogram feature - PLC functionality - Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
-
Reverse reactive power (kVAr) (32RV
-
Frequency (Hz)
-
Low coolant temperature
-
3 Analog inputs
-
Cat connect
-
kVAr (per phase, average & percent)
-
Warning/shutdown with common LED indication of shutdowns for:
-
Engine cycle crank
-
Failure to start (overcrank)
-
Programmable protective relaying functions:
-
Emergency stop
-
Customer data link (Modbus RTU
-
Engine cool-down timer
-
Volts (L-L & L-N)
-
Amps (per phase & average)
-
Operating hours
-
High coolant temperature
-
Digital indication for:
-
1 programmable digital outputs
-
4 programmable relay outputs (Form A)
Cooling System
+
-
-
Certified standard PGS provided
Exhaust System
+
-
-
Flanged faced outlet(s)
-
Dry exhaust manifold
Fuel System
+
-
-
Secondary fuel filters
-
Fuel cooler; not included with packages without radiator
-
Flexible fuel lines - shipped loose
-
Fuel priming pump
General
+
-
-
Right hand servicing
-
Flywheel and flywheel housing - SAE No. 00
-
SAE standard rotation
Generator And Attachments
+
-
-
NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
-
NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
-
Winding temperature detectors
-
Winding temperature detectors
-
Permanent magnet excitation (PMG)
-
Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
-
Six lead
-
Permanent magnet excitation (PMG)
-
Internal excitation (IE)
-
3 Phase brushless, Salient pole
-
Winding temperature detectors
-
Medium voltage:
-
Random wound
-
Anti-condensation space heater
-
Low voltage:
-
High voltage:
-
Busbar connections, top center mounted, top cable entry
-
Form wound
-
Busbar connections, right side extension box, bottom cable entry
-
Form wound
-
NEMA standard hole pattern
-
NEMA standard hole pattern
Lubrication System
+
-
-
Fumes disposal
-
Lubricating oil
-
Gear type lube oil pump
-
Oil filter, filler and dipstick
-
Oil drain lines and valve
-
Integral lube oil cool
Mounting System
+
-
-
Rails - engine/generator/radiator mounting
-
Anti-vibration mounts (shipped loose)
-
Rubber anti-vibration mounts - shipped loose
Starting System
+
-
-
Battery and battery rack w/cables
-
45 Amp Charging alternator
-
Battery disconnect switch
-
24 Volt electric starting motor
Optional Equipment:
Control System
+
-
Controller: EMCP 4.2B
Local annunciator module: [ ] NFPA 110 [ ] Custom
Air Inlet System
+
-
Dual element air cleaner
Single element filter
Cooling System
+
-
Standard ambient radiators
Coolant
Optional installed ATAAC radiators
Optional installed radiators
Water level switch gauges
Standard ambient ATAAC radiators
Engine Options
+
-
Starting motors: [ ] Standard [ ] Heavy duty
Batteries: [ ] Standard (1400 CCA) [ ] Heavy Duty (2800 CCA)
Starting aids: [ ] 220V 50 Hz Jacket water heater
Battery charger: [ ] 10A [ ] 20A [ ] 35A
Air cleaner: [ ] Single element air cleaners [ ] Dual element air cleaners [ ] Heavy duty air cleaners
Muffler: [ ] Industrial Grade
Crankcase System
+
-
No explosion relief valves
Ventilation system
Explosion relief valves
Alternators
+
-
Temperature rise (over 40°C ambient): [ ] 150°C [ ] 125°C [ ] 105°C [ ] 80°C
Exhaust System
+
-
Y Adapters
Tier 4 clean emissions module
Tier 4 dosing cabinet
Elbows
Tier 4 clean emission MOD Kits
Exhaust offset
Flanges
Flange and exhaust expanders
Flexible fittings
Mufflers
Clean emission parts
Fuel System
+
-
Fuel priming pumps (Tier 4) - Manual or electric
Primary fuel filter
General
+
-
US aid emblem
Special paint (Colors other than Caterpillar yellow or high performance paints)
The following options are based on regional and product configuration:
UL 2200 package
Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
Generators And Attachments
+
-
High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
Generator conversion
Low / Medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
Thermostat for space heater
Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame
Alternator air cleaner
Differential current transformers (DCT)
High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
Differential current transformers (DCT) 8.7 kV and 15 kV classes
Space heater kit
Power Termination
+
-
Circuit breaker operation: [ ] Electrical
Circuit breaker rating: [ ] 2000A [ ] 2500A [ ] 3200A [ ] 4000A
Circuit breaker trip unit: [ ] LSI [ ] LSIG [ ] LSIG-P
Power termination: [ ] Busbar [ ] Circuit breaker
Extended Service Contract (esc)
+
-
Extended Service Contract (ESC): [ ] 2 Year [ ] 3 Year [ ] 5 Year
Instrumentation
+
-
Pyrometer and Thermocouples
Lubrication System
+
-
Lube oil in standard sump
Prelube pumps
Oil level regulator
Mounting System
+
-
Puck style low efficiency isolators
Spring type vibration isolators
IBC vibration isolators
Power Connections
+
-
Ground cables between generator and terminal box
Neutral ground connections
2700 Frame, four lead, four terminal
Rear power connections
Right side power connections
Left side power connections
Low voltage Circuit breakers
Center post busbars
Special Tests / Reports
+
-
Generator test report
OSHPD Certification
Canadian Standards Association certification
PGS Test report @ 1.0 power factor
IBC Certification
Fuel consumption test
Generator set fuel consumption test
PGS Test report @ 0.8 power factor
Standard engine test charge
Torsional vibration analysis reports
Starting And Charging
+
-
Electric starting motors
Air pressure regulator
Starter cover
Air starting motors
24 Volt battery set - Dry
10, 20, 35 and 50 Amp Battery chargers
Jacket water heaters
Engine barring device
Extended Service Coverage
+
-
Platinum, Gold and Silver coverage