3516E Generator Set
360° Exterior View
At a Glance
|
|
|
|
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
+ -Maximum Rating | 3500 kVA |
Minimum Rating | 3000 kVA |
Emissions/Fuel Strategy | Tier 2 Equivalent - 1808 rpm |
Voltage | 380 to 11000 volts |
Frequency | 50 Hz |
Speed | 1808 rpm |
Duty Cycle | Standby, Mission Critical |
Engine Specifications
+ -Engine Model | 3516E, V-16, 4-Stroke Water-Cooled Diesel |
Bore | 6.69in |
Stroke | 8.46in |
Displacement | 4765in³ |
Compression Ratio | 14.7:1 |
Aspiration | ATAAC |
Fuel System | Electronic Unit Injection |
Governor Type | Adem™5 |
Generator Set Dimensions
+ -Length - Minimum | 353.3in |
Length - Maximum | 363.1in |
Width - Minimum | 104in |
Width - Maximum | 104in |
Height - Minimum | 132.6in |
Height - Maximum | 131.6in |
Dry Weight - Genset (minimum) | 47620lb |
Dry Weight - Genset (maximum) | 52911lb |
Standard Equipment:
Air Inlet System
+ --
Air cleaner; single element canister type
Control System
+ --
Text alarm/event descriptions
-
Emergency stop pushbutton
-
IVR includes reactive droop capability
-
KVAR / PF modes
-
EMCP 4.2B
-
3 Phase voltage sensing
-
Generator mounted - rear facing
-
Generator set packages include:
-
24 Volt DC operation
-
Caterpillar's voltage regulator
-
RFI suppression
-
Environmental sealed front face
-
Limiter and exciter diode monitor
-
Min / max exciter
-
Controls:
-
Speed adjust
-
Alarm acknowledge
-
Auto/start/stop control
-
Engine cycle crank
-
Engine cool
-
Customizable screens
-
PLC functionality
-
Lamp test
-
Load histogram feature
-
Accessory module data link
-
Reverse power (kW) (32)
-
6 Customer programmable digital inputs
-
3 Phase
-
+/- 2% accuracy
-
High coolant temperature
-
0 True RMS AC metering
-
Programmable protective relaying functions:
-
Reverse reactive power (kVAr) (32RV)
-
Communications:
-
Generator phase sequence
-
Over/under voltage (27/59)
-
Overcurrent (50/51)
-
RPM
-
Number of I/O varies on options selected
-
Overspeed
-
Serial annunciator module data link
-
Low coolant temperature
-
4 Programmable relay outputs (Form A)
-
1 Programmable relay outputs (Form C)
-
3 Analog inputs
-
Over/under frequency (81 o/u)
-
Digital indication for:
-
Low coolant level
-
Failure to start (overcrank)
-
Cat connect
-
1 Programmable digital outputs
-
DC volts
-
Operating hours
-
Coolant temperature
-
Oil pressure (psi, kPa or bar)
-
Amps (per phase & average)
-
Power factor (per phase & average)
-
Frequency (Hz)
-
Volts (L-L & L-N)
-
kW (per phase, average & percent)
-
kVA (per phase, average & percent)
-
kVAr (per phase, average & percent)
-
Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level -
-
Low oil pressure
-
kW-hr (total)
-
kVAr-hr (total)
Cooling System
+ --
ATAAC - 3516E package radiators shipped installed
-
Certified standard PGS provided
Exhaust System
+ --
Flanged faced outlet(s)
-
Dry exhaust manifold
Fuel System
+ --
Secondary fuel filters
-
Fuel cooler; not included with packages without radiator
-
Flexible fuel lines - shipped loose
General
+ --
Right hand servicing
-
Caterpillar yellow with high gloss black rails and radiator
-
SAE standard rotation
-
Flywheel and flywheel housing - SAE No. 00
Generator And Attachments
+ --
NEMA standard hole pattern
-
Medium voltage:
-
Anti-condensation space heater
-
NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
-
Winding temperature detectors
-
High voltage:
-
Busbar connections, right side extension box, bottom cable entry
-
Form wound
-
Low voltage: Random wound - Internal excitation (IE) - Winding temperature detectors - NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby) - Busbar connections, top center mounted, top cable entry - NEMA standard hole pattern
-
6 Lead
-
Permanent magnet excitation (PMG)
-
3 Phase brushless, Salient pole
-
Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
Governing System
+ --
ADEM A5
Literature
+ --
English
Lubrication System
+ --
Integral lube oil cool
-
Oil filter, filler and dipstick
-
Oil drain lines and valve
-
Gear type lube oil pump
-
Lubricating oil
-
Fumes disposal
Mounting System
+ --
Rails - Engine/generator/radiator mounting
-
Anti-vibration mounts (shipped loose)
-
Rubber anti-vibration mounts - shipped loose
Starting System
+ --
24 Volt electric starting motor
-
Battery disconnect switch
-
Battery and battery rack w/cables
-
45 Amp Charging alternator
Optional Equipment:
Control System
+ -EMCP 4.3, EMCP 4.4
Air Inlet System
+ -Single element filter
Dual element air cleaner
Cooling System
+ -Standard ambient radiators
Water level switch gauges
Optional installed ATAAC radiators
Optional installed radiators
Coolant
Standard ambient ATAAC radiators
Crankcase System
+ -Ventilation system
No explosion relief valves
Explosion relief valves
Exhaust System
+ -Y Adapters
Fuel System
+ -Fuel priming pumps (Tier 4) - Manual or electric
Primary fuel filter
General
+ -Special paint (Colors other than Caterpillar yellow or high performance paints)
US aid emblem
Generators And Attachments
+ -Space heater
Differential current transformers (DCT) 8.7 kV and 15 kV classes
Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
Alternator air cleaner
Thermostat for space heater
Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
Generator conversion
Instrumentation
+ -Pyrometer and thermocouples
Lubrication System
+ -Oil level regulator
Prelube pumps
Lube oil in standard sump
Mounting System
+ -Puck style low efficiency isolators
Spring type vibration isolators
IBC vibration isolators
Power Connections
+ -Neutral ground connections
Center post busbars
Right side power connections
Special Tests / Reports
+ -Generator set fuel consumption test
PGS Test report @ 1.0 power factor
Standard engine test charge
Canadian Standards Association certification
Generator test report
IBC Certification
OSHPD Certification
Fuel consumption test
Torsional vibration analysis reports
PGS Test report @ 0.8 power factor
Starting And Charging
+ -Starter cover
Air pressure regulator
10, 20, 35 and 50 Amp Battery chargers
24 Volt battery set - Dry
Jacket water heaters
Air starting motors
Electric starting motors
Engine barring device
Extended Service Coverage
+ -Platinum, Gold and Silver coverage