G3516C Gas Generator Set
360° Exterior View
At a Glance
|
|
|
|
Overview
G3516C Generator Set
Generator Set Specifications
+ -Continuous Rating | 1660 ekW |
Fuel Type | Natural Gas |
Maximum Electrical Efficiency | 37.70% |
Maximum Standby Rating | 1500 |
Frequency | 50 / 60 Hz |
RPM | 1500/1800 |
Engine Specifications
+ -Engine Model | G3516C |
Displacement | 4210in³ |
Aspiration | TA |
Bore | 6.7in |
Stroke | 7.5in |
Generator Set Dimensions
+ -Length | 219in |
Width | 72in |
Height | 92in |
Dry Weight - Genset | 31226lb |
Standard Equipment:
Air Inlet
+ --
Two-element single-stage air cleaner with enclosure and service indicator
Control Panels
+ --
EMCP 4.3
Cooling
+ --
Jacket water and SCAC driven pumps and bypass lines
-
2nd Stage SCAC-Cat Flange
-
Engine driven water pumps for jacket water and aftercooler
-
Jacket water and SCAC thermostats
-
ANSI/DN customer flange connections for JW inlet and outlet
-
Cat flanges on SCAC circuit
Exhaust
+ --
Integrated Sensing Module (ISM)
-
Cat-flanged face outlet on turbocharger
-
Provides exhaust port temperatures and stack temperature to customer supplied screen via CCM
-
Dry exhaust manifolds, insulated and shielded
Fuel System
+ --
24V ETR Gas Shutoff Valve
-
Engine installed, fuel metering valve
-
Throttle plate, 24V DC actuator, controlled by ECM
-
Fuel system is sized for 31.5 to 47.2 MJ/NM3 dry pipeline natural gas with pressure of 10.2 to 34.5KPa to the engine fuel control valve
-
Fuel Filter
Ignition System
+ --
Individual Cylinder Detonation Sensitive Timing (DST)
-
Electronic Ignition System (controlled by ECM)
Fuel System
+ --
Electronic fuel metering valve
Generator
+ --
Anti-condensation space heater
-
Busbar connections
-
Class H Insulation & Class F temperature rise
-
Reactive Droop
-
Permanent Magnet Excitation
-
3-phase brushless, salient pole
-
Caterpillar's Digital Voltage Regulator (CDVR) with 3-phase sensing and KVAR/PF control
-
SR4B
-
Winding temperature detectors
General
+ --
RH Service
-
Operation and maintenance manuals
-
Crankshaft Vibration Damper and Guard
-
Parts Book
Starting/charging
+ --
24V starting motors
Optional Equipment:
Air Inlet
+ -Vertical, horizontal dual element air cleaner
Enclosure mounting brackets and piping
Air cleaner with precleaner
Control Panel
+ -Local NFPA99-110 Alarm Module w/LEDs
Synchronizing Module
Remote 24V 8/16 Light Annunciator
Engine Failure Relay
PL1000E/PL1000T Communications Module
Custom 8-Light Alarm Module
Cooling
+ -Inlet/Outlet connections
Jacket water coolant heater
Aftercooler air lines, aftercooler core replacement
Exhaust
+ -Flexible Fittings
14" Flange Kit
406 mm Elbow Kits
406 mm flange kits
Mufflers (15/18/25 dBA Attenuation) and spark-arresting muffler with ANSI companion flanges
16" Spark Arresting Muffler
356-406mm Flange and Exhaust Expander
15/18/25 dBA Muffler Attenuation
Fuel System
+ -207-276kPa, 30-40 psi gas knockdown regulator
14-69 kPa (2-10 psi) gas pressure regulator
24VDC Gas Shutoff Valve, Gas Knockdown Regulator
Fuel Filter, Gas Filter
Generator
+ -Cable access box
8.7/15 kV Cross, Differential, Current Transformers (CCCT, DCT, CT)
Medium and high voltage generators and attachment
480/4160/13200 Volt Generator Options (60 Hz)
Generator air filter
Bearing temperature detectors
European Bus Bars
415/400/380, 3300/6600/11000 Volt Generator Options (50 Hz)
Annunciator Modules
Generator Removal
Low voltage extension box
Governing System
+ -Load share module
General
+ -Special paint order
Tool set
US AID Emblem
Barring group
Digital diagnostic tool
Starting/charging
+ -60A, 24V charging alternator (requires engine driven pumps)
Battery removal
20A battery charger
Battery disconnect switch
Battery with cables and rack (shipped loose)