Switchgear and Paralleling Controls

  • Cat EGP Switchgear

    Configuration
    Traditional customizable PLC based floor standing switchgear capable of controlling and monitoring multiple utilities, generators, and loads
    Modes of Operation
    Multi-unit Island and multi-unit standby mode with optional redundant controls and components.
    Application
    LV and MV (208V - 38 kV)
    ANSI Protective Devices
    15/25, 27/59, 81 O/U, 32, 40, 50, 51
  • Cat XLM Switchgear

    Configuration
    Traditional customizable PLC based floor standing switchgear capable of controlling and monitoring multiple utilities, generators, and loads
    Modes of Operation
    Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power
    Application
    LV and MV ( 208V - 38 kV
    ANSI Protective Devices
    15/25, 27/59, 81 O/U, 32, 40, 50, 51
  • Emergency Transfer Load manager

    Configuration
    Wall mounted paralleling control system that monitors and controls a single generator and a single utility.
    Modes of Operation
    Utility Import, Export, and base load operations, Peak shaving, and Emergency Standby. Closed Transition to/from Generator Power
    Application
    LV and MV (208V-32kV)
    ANSI Protective Devices
    15/25. 27/59, 81 O/U, 32, 40, 50, 51
  • Engine Generator Integrated Switchgear

    Configuration
    Floor Standing modular switchgear paralleling system (Master Breaker Panel for the first 2 gensets, separate structures for up to 8 additional gensets , utility, and load control/distribution)
    Modes of Operation
    Emergency Standby with redundant master control. Utility paralleling, peak shaving, and closed transition to/from Generator Power (with optional utility control panel)
    Application
    LV only (208V - 480V)
    ANSI Protective Devices
    15/25. 27/59, 81 O/U, 32, 40, 90 (Industrial Grade)
  • Engine Paralleling and Integration Control (EPIC)

    Configuration
    Remote modular paralleling control system (Master Control Panel for the first 2 gensets, separate add-on control panels for up 8 more gensets, and optional control panel for 1 utility breaker)
    Modes of Operation
    Emergency Standby with redundant master control, Utility paralleling, peak shaving, and closed transition to/from Generator Power (with optional utility control panel)
    Application
    LV and MV (208V-27kV)
    ANSI Protective Devices
    15/25. 27/59, 81 O/U, 32, 40, 90 (Industrial Grade)