D50 GC Generator Set
- products
- new products
- power systems
- diesel generator sets
- D50 GC Generator Set
At a glance data:
Maximum Rating:
50 ekW
Minimum Rating:
50 ekW
Emissions/Fuel Strategy:
U.S. EPA Cert., Tier 3, SCAQMD Compliant
Voltage:
208 to 600 Volts
machine
new
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Print
Electric Power Ratings Guide
D50 GC, C4.4, 60 Hz 50 ekW, EPA Tier III Compliant Emissions Spec Sheet
D50 GC, 60 Hz 50 ekW, SCAQMD Complaint (Meets nonroad U.S. EPEPA Tier 3 equivalent emission standards) Spec Sheet
GCCP 1.2 Control Panel Data Sheet
GCCP 1.5 Control Panel Data Sheet
Cat® GC Generator Set Brochure for North America
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Category:
Diesel Generator Sets
Category:
Diesel Generator Sets
Brand:
Cat
Brand:
Cat
Generator Set Specifications
Maximum Rating:
50 ekW
Minimum Rating:
50 ekW
Emissions/Fuel Strategy:
U.S. EPA Cert., Tier 3, SCAQMD Compliant
Voltage:
208 to 600 Volts
Frequency:
60 Hz
Speed:
1800 rpm
Duty Cycle:
Standby
Engine Specifications
Engine Model:
C4.4, In-line 4, 4-cycle diesel
Bore:
4.1in
Stroke:
5in
Displacement:
269in
Compression Ratio:
18.2:1
Aspiration:
Turbocharged
Fuel System:
Common Rail
Governor Type:
Mechanical, ADEM™A4
Generator Set Dimensions
Length - Maximum:
77.2in
Width - Maximum:
43.3in
Height - Maximum:
48in
Dry Weight - Genset (maximum):
2055lb
Standard Equipment
certificates
- IBC seismic and wind Certifications
air inlet system
- Air cleaner
- Cartridge type air filter
circuit breakers
- Second circuit breaker box
- Power terminal strip
- Breakers (100% UL rated)
- 3-Pole 100% rated
charging system
- NFPA battery charger UL10A 120VAC
control panel
- GCCP 1.2 Control panel
exhaust system
- Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
fuel system
- Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
cooling system
- Fan drive, battery charging alternator drive
- Caterpillar extended life coolant
- Radiator and cooling fan with guards
- Coolant drain line with valve
- Radiator stone guard
control panels
- NFPA110 bundle includes:
- WCA1 Low coolant temperature alarm
- FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected
- WSS1 Low coolant level shut down
- PBC10NU NFPA battery charger
- Oil temperature gauge and sender
- PAA1 Panel mounted audible alarm
- A Coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
- Audible alarm
- Remote E-stop button
- Ground fault relay
- Discrete I/O module
- Remote annunciator module
- Volt free contacts genset run and common alarm
- Fuel level reading
- Protective devices:
- Low coolant temperature alarm
- Low coolant level shutdown
- Overload shutdown via breaker
generator
- 12 Leads
governing system
- Mechanical and electrical governing system - model dependent
lube system
- Lubricating oil
- Oil drain line with valve
general
- Engine and alternator pre-paint, Caterpillar yellow
starting/charging system
- Batteries
- 24V battery with rack and cables
Optional Equipment
certificates
- IBC seismic and wind Certifications
air inlet system
- Cartridge type air filter
alternator system
- R Frame auxilliary winding
charging system
- NFPA battery charger UL10A 120VAC
circuit breakers
- Breakers (100% UL rated)
- Power terminal strip
- 3-Pole 100% rated
- Second circuit breaker box
control panels
- Volt free contacts genset run and common alarm
- Oil temperature gauge and sender
- Remote E-stop button
- Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
- Audible alarm
- Remote annunciator module
- Discrete I/O module
- NFPA110 bundle includes: FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low coolant level shut down - WCA1 Low coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA battery charger - A Coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
- Ground fault relay
cooling system
- Radiator transition flange
enclosures
- External emergency stop
- Sound attenuated enclosure, Level 2
- Panel viewing window
exhaust system
- 10, 25 and 35 dBA silencer systems
- Overhead silencer mounting kit
fuel system
- 5 Gallon spill containment
- 209 and 394 gallon sub-base fuel tanks
- Tank riser
- Emergency vent pipe
- 5 Gallon fill containment
heating elements
- Coolant heater
- Wiring for canopy space heater
- Battery heater
- Lube oil sump heater
- Anti-condensation heater
- Wiring for canopy space heater
- Jacket water heater
generators
- Permanent magnet excitation (PMG) generator
- Permanent magnet excitation (PMG) generator
mounting system
- Seismic vibration isolators
tests
- 4 Hour factory test
- PGS Test report @ 1.0 power factor
- PGS Test report @ 0.8 power factor
- Generator test report
Similar Products
C9 Generator Set
Maximum Rating:
50 ekW
Minimum Rating:
50 ekW
Emissions/Fuel Strategy:
U.S. EPA Cert., Tier 3, SCAQMD Compliant
Voltage:
208 to 600 Volts
3516C Tier 4 Final
Maximum Rating:
50 ekW
Minimum Rating:
50 ekW
Emissions/Fuel Strategy:
U.S. EPA Cert., Tier 3, SCAQMD Compliant
Voltage:
208 to 600 Volts
3516B Generator Set
Maximum Rating:
50 ekW
Minimum Rating:
50 ekW
Emissions/Fuel Strategy:
U.S. EPA Cert., Tier 3, SCAQMD Compliant
Voltage:
208 to 600 Volts