C32 (60 Hz)
- new - Products
- C32 (60 Hz)
At a glance data:
Maximum Rating:
1250 ekW
Minimum Rating:
830 ekW
Emissions/Fuel Strategy:
Low Fuel, Tier 2 Nonroad Stds
Voltage:
220 to 4160 Volts
Print
Electric Power Ratings Guide
C32, 60 Hz, 1000 ekW Standby/MC, 910 ekW Prime, 830 ekW Cont., Low Fuel Consumption Spec Sheet
C32, 60 Hz, 1000 ekW Standby/MC, 910 ekW Prime, 830 ekW Cont., U.S. EPA Certified for Emergency Stationary Applications (Tier 2) Spec Sheet
C32, 60 Hz, 1250 ekW Standby/MC, 1135 ekW Prime, Low Fuel Consumption Spec Sheet
C32, 60 Hz, 1250 ekW Standby/MC, 1135 ekW Prime, U.S. EPA Certified for Emergency Stationary Applications (Tier 2) Spec Sheet
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Category:
Diesel Generator Sets
Category:
Diesel Generator Sets
Brand:
Cat
Brand:
Cat
Generator Set Specifications
Maximum Rating:
1250 ekW
Minimum Rating:
830 ekW
Emissions/Fuel Strategy:
Low Fuel, Tier 2 Nonroad Stds
Voltage:
220 to 4160 Volts
Frequency:
60 Hz
Speed:
1800 rpm
Duty Cycle:
Standby, Mission Critical, Prime, Continuous
Engine Specifications
Engine Model:
C32 TA, V-12, 4-Stroke Water-Cooled Diesel
Bore:
5.71in
Stroke:
6.38in
Displacement:
1958.86in³
Compression Ratio:
15.0:1
Aspiration:
TA
Fuel System:
MEUI
Governor Type:
Adem™A4
Generator Set Dimensions
Length - Minimum:
164in
Length - Maximum:
172.7in
Width - Minimum:
66.3in
Width - Maximum:
87.7in
Height - Minimum:
85.1in
Height - Maximum:
86.4in
Dry Weight - Genset (minimum):
14700lb
Dry Weight - Genset (maximum):
16755lb
Standard Equipment
air inlet system
- Single element canister type with service indicator
control panel
- Warning shutdowns
- GCCP 1.2
- Digital Indicators
- Communications
- Control features
- Programmable protective relaying functions
cooling system
- Caterpillar extended life coolant
- ATAAC
- Coolant drain line with valve
- Low coolant level sensor
- Fan and belt guards
- Radiator fan and fan drive
exhaust system
- 203 mm (8 in) ID round flanged outlet
- Exhaust manifold - dry
fuel system
- Fuel cooler
- Fuel priming pump
- Secondary fuel filters
- Primary fuel filter with water separator
general
- RH service
- Caterpillar yellow with high gloss black rails & radiator
- SAE standard rotation
- Flywheel and flywheel housing-SAE
generators and attachments
- Class H temperature rise at 40C ambient
- 3 Phase brushless
- Permanent magnet excitation (PMG)
- Winding temperature detectors
- Integrated voltage regulator (IVR)
- Reactive droop
- IEC standard hole pattern
- NEMA Class H insulation
- Busbar connections, top center mounted, top cable entry
- Salient pole
- 6 Lead
- Internal excitation (IE)
governing system
- ADEM(tm) A4
lube system
- Gear type lube oil pump
- Oil drain lines and valve
- Fumes disposal
- Lubricating oil
- Integral lube Oil cooler
- Oil filter, filler and dipstick
mounting system
- Rubber anti-vibration mounts
- Rails - Engine/generator/radiator mounting
power termination
- Busbar
starting and charging
- 45 Amp Charging alternator
- 24 Volt electric starting motor
- Battery disconnect switch
- Battery, rack and cables
Optional Equipment
air inlet system
- Standard air cleaners
- Heavy duty air cleaner
- Dual element air cleaner
circuit breakers
- Shrouds
- 1600, 2000, 2500 and 3200 Amp, 3 Pole, IEC-Rated Circuit breakers
- Center posts busbars
- Enclosures - Control packaging
- 400, 800, 1200, 1600, 2000, 2500 and 3000 Amp, 3 Pole, UL-100% Rated Circuit breakers
- Circuit breaker wiring groups
- Power connection covers
- Cable supports
- 800, 1600, 2000, 2500 and 3200 Amp, 4 Pole, IEC rated Circuit breakers
control panels
- CAT ECS 200
cooling system
- High ambient radiator
- Extended life coolant
- Standard radiator
- Radiator duct flange
- Certified radiator
enclosures
- Premium sound attenuated enclosure
- Cold weather bundle
- Color options
- DC lighting package
- Sound attenuated enclosure
- AC Panel, outlets and lights
- Panel bracket
- Enclosure fuel tank options
- Enclosure louvers - fixed and motorized
exhaust system
- Elbow mounting kit
- Mufflers
- Guard and shield system
- Flange and exhaust expanders
- Flexible fittings
- All C32 engines have 203 mm (8 in) exhaust outlets
- Flanges
- Exhaust through the wall kit
general
- US aid emblem
- Special paint
generator and attachments
- Medium voltage optional generators
- Low voltage optional generators
lube system
- Oil level regulator
- Oil pan
- Prelube manual sump pump
mounting system
- Spring type vibration isolators
- IBC vibration isolators
- Mounting base types
- Standard package isolators
power connections
- Center post busbars
- Low voltage connection cables
- Neutral grounding connection
power termination
- Circuit breakers, UL listed
- Circuit breakers, IEC compliant
special tests / reports
- Standard engine test
- IBC seismic Certifications
- PGS Test report @ 1.0 power factor
- Custom generator TVA report
- Generator test report
- Standard genset Torsional Vibration Analysis (TVA) report
- PGS Test report @ 0.8 power factor
- CSA test and certification
- OSHPD seismic Certifications
starting / charging
- 10 Amp enclosure Battery charger
- 35 Amp Battery charger
- Space heater
- Jacket water heater
- Electric starting motor - Standard/heavy duty
- Heavy duty starting system
- 10 Amp Battery charger
- 20 Amp Battery charger
Cat Switchgear
Maximum Rating:
1250 ekW
Minimum Rating:
830 ekW
Emissions/Fuel Strategy:
Low Fuel, Tier 2 Nonroad Stds
Voltage:
220 to 4160 Volts
C27 and C32 Sound Attenuated Enclosure
Maximum Rating:
1250 ekW
Minimum Rating:
830 ekW
Emissions/Fuel Strategy:
Low Fuel, Tier 2 Nonroad Stds
Voltage:
220 to 4160 Volts
Similar Products
C9 Generator Set
Maximum Rating:
1250 ekW
Minimum Rating:
830 ekW
Emissions/Fuel Strategy:
Low Fuel, Tier 2 Nonroad Stds
Voltage:
220 to 4160 Volts
3516C Tier 4 Final
Maximum Rating:
1250 ekW
Minimum Rating:
830 ekW
Emissions/Fuel Strategy:
Low Fuel, Tier 2 Nonroad Stds
Voltage:
220 to 4160 Volts
3516B Generator Set
Maximum Rating:
1250 ekW
Minimum Rating:
830 ekW
Emissions/Fuel Strategy:
Low Fuel, Tier 2 Nonroad Stds
Voltage:
220 to 4160 Volts