C9 Generator Set
- new - Products
- C9 Generator Set
At a glance data:
Standby Rating:
200/250/300 ekW
Prime Power Rating:
180/225/275 ekW
Emissions/Fuel Strategy:
U.S. EPA Tier 3 Certified
Voltage:
220 to 480 Volts
machine
new
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Print
Electric Power Ratings Guide
C9 60 Hz, 200 ekW, Tier III Non-Road Emissions Compliant Spec Sheet
C9 60 Hz, 250 ekW, Tier III Non-Road Emissions Compliant Spec Sheet
C9 60 Hz, 300 ekW, Tier III Non-Road Emissions Compliant Spec Sheet
200 ekW - 300 ekW Spec Sheet
DE200SE0 60 Hz 250 kVA, Non Certified Emissions Spec Sheet
DE250E0 60 Hz 313 kVA, Non Certified Emissions Spec Sheet
DE275SE0 60 Hz 344 kVA, Non Certified Emissions Spec Sheet
DE300SE0 60 Hz 375 kVA, Non Certified Emissions Spec Sheet
DE300SE3 60 Hz 375 kVA, EU Stage III Emissions Compliant Spec Sheet
200 - 300 ekW Spec Sheet
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Category:
Diesel Generator Sets
Category:
Diesel Generator Sets
Brand:
Cat
Brand:
Cat
Generator Set Specifications
Standby Rating:
200/250/300 ekW
Prime Power Rating:
180/225/275 ekW
Emissions/Fuel Strategy:
U.S. EPA Tier 3 Certified
Voltage:
220 to 480 Volts
Frequency:
60 Hz
Speed:
1800 rpm
Duty Cycle:
Standby, Prime
Engine Specifications
Engine Model:
C9 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore:
4.41in
Stroke:
5.87in
Displacement:
537.01in³
Compression Ratio:
16.1:1
Aspiration:
Air to Air Aftercooled
Fuel System:
Hydraulic electronic unit injection
Governor Type:
Adem™A4
Generator Set Dimensions
Length - Maximum:
157in
Width - Maximum:
47.5in
Height - Maximum:
73.5in
Standard Equipment
air inlet system
- Turbocharger
- Air cleaner, light duty with disposable paper filter
- Aftercooler core
exhaust system
- Exhaust manifold - dry
- Stainless steel exhaust flex, gaskets, rain cap & SAE exhaust flange for customer use - shipped loose
control panels
- GCCP 1.3
cooling system
- Caterpillar extended life coolant
- Fan drive, battery charging alternator drive
- Coolant drain line with valve
- Radiator and cooling fan with guard
fuel system
- Standard open set fuel tank/base supplied
- Fuel cooler
- Primary fuel filter w/integral water separator and secondary filter
- Base, formed steel with single wall integral 8-hour fuel tank
- Fuel priming pump
generators and generator attachments
- Mandatory option circuit breaker, IEC, 3 pole mounted in power centre
- IP23 Protection
- 12 Leads
- Segregated low voltage (AC/DC) wiring panel
- Insulation Class H and temperature rise
- Power centre, IP22
- Brushless, self-excited 2/3 pitch, random wound
- Voltage regulator (single phase sensing)
governing system
- Cat electronic governor (ADEM A4)
mounting system
- Captive linear vibration isolators between base and engine-generator
- Includes lifting provisions and termination points for coolant and lube oil drain lines
starting / charging system
- 24V battery with rack and cables
general
- Engine and alternator re-paint, Caterpillar yellow
lube system
- Oil cooler
- Oil drain valves
- Fumes disposal, piped to front of radiator
- Lubricating oil
- Oil filter and dipstick
- Oil drain lines with valve; piped to edge of base
Optional Equipment
certifications
- European Certificate for Conformance
- Global Certification for CIS
air inlet system
- Single element air cleaner
circuit breakers
- 4 Pole (IEC-100% rated) Circuit breaker upgrades: 400, 630, 800 and 100 amps
control panels
- Control panel protective devices: Earth fault relay ; Earth leakage ground fault ; overload shutdown via breaker ; Low fuel level shutdown ; Low fuel level alarm ; Fuel level sensor
- Control panel Options: GCCP 1.4 ; Volt free contacts ; Local alarm horn ; Oil temperature displays
cooling system
- Radiator duct flange
- Low coolant temperature alarm
enclosures
- High ambient sound attenuated enclosure
- Sound attenuated enclosure
exhaust system
- 5 - 6 inch flange adaptor
- 6 inch flange
- Mufflers - End in/end out; 10 dBA or 25 dBA attenuation
- 5 and 6 inch elbow kits
fuel system
- Integral dual wall fuel tank base
generators and attachments
- Permanent magnet excitation (PMG) generator
- Oversize, AREP, CIP generators
mounting system
- Narrow skid base
starting / charging system
- Jacket water heater
- 5 Amp single Battery charger
- Battery disconnet switch
C9 230-275kVA ACERT
Standby Rating:
200/250/300 ekW
Prime Power Rating:
180/225/275 ekW
Emissions/Fuel Strategy:
U.S. EPA Tier 3 Certified
Voltage:
220 to 480 Volts
C9 275-330 kVA ACERT
Standby Rating:
200/250/300 ekW
Prime Power Rating:
180/225/275 ekW
Emissions/Fuel Strategy:
U.S. EPA Tier 3 Certified
Voltage:
220 to 480 Volts
Similar Products
C9 Generator Set
Standby Rating:
200/250/300 ekW
Prime Power Rating:
180/225/275 ekW
Emissions/Fuel Strategy:
U.S. EPA Tier 3 Certified
Voltage:
220 to 480 Volts
3516C Tier 4 Final
Standby Rating:
200/250/300 ekW
Prime Power Rating:
180/225/275 ekW
Emissions/Fuel Strategy:
U.S. EPA Tier 3 Certified
Voltage:
220 to 480 Volts
3516B Generator Set
Standby Rating:
200/250/300 ekW
Prime Power Rating:
180/225/275 ekW
Emissions/Fuel Strategy:
U.S. EPA Tier 3 Certified
Voltage:
220 to 480 Volts