Type

+ -
  • 3412C Generator Set

    Minimum Rating
    591 ekW
    Maximum Rating
    800 ekW
    Emissions/Fuel Strategy
    Low Fuel Consumption
    Voltage
    208 to 600 Volts
  • 3412C Generator Set

    Minimum Rating
    680 kVA
    Maximum Rating
    900 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption
    Voltage
    208 to 600 Volts
  • 3512 Generator Set

    Minimum Rating
    1000 kVA
    Maximum Rating
    1400 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption
    Voltage
    220 to 13800 Volts
  • 3512 Generator Set

    Minimum Rating
    890 ekW
    Maximum Rating
    1250 ekW
    Emissions/Fuel Strategy
    Low Fuel Consumption
    Voltage
    220 to 13800 Volts
  • 3512 Generator Set

    Minimum Rating
    1000 kVA
    Maximum Rating
    1400 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions
    Voltage
    400 to 415 Volts
  • 3512 with Upgradeable Package

    Minimum Rating
    890 eKW
    Maximum Rating
    1250 eKW
    Emissions/Fuel Strategy
    Optimized for Low Fuel Consumption
    Voltage
    220 to 13800 Volts
  • 3512B (50 Hz) Generator Set

    Minimum Rating
    1320 kVA
    Maximum Rating
    1875 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions
    Voltage
    220 to 13800 Volts
  • 3512B (50 Hz) India Market Only

    Minimum Rating
    1500 kVA
    Maximum Rating
    1500 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption
    Voltage
    Low (415 Volts), Medium and High Voltage
  • 3512B Diesel Generator Set

    Minimum Rating
    1230 ekW
    Maximum Rating
    1500 ekW
    Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions
    Voltage
    220 to 13800 Volts
  • 3512B Diesel Generator Set

    Minimum Rating
    1320 kVA
    Maximum Rating
    1750 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions
    Voltage
    400 to 415 Volts
  • 3512B Diesel Generator Set

    Minimum Rating
    1230 eKW
    Maximum Rating
    1500 eKW
    Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions
    Voltage
    380 to 480 Volts
  • 3512C Generator Set

    Minimum Rating
    1230 ekW
    Maximum Rating
    1500 ekW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)
    Voltage
    220 to 13800 Volts
  • 3512C Generator Set

    Minimum Rating
    1750 ekW
    Maximum Rating
    1750 ekW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)
    Voltage
    380 to 13800 Volts
  • 3516 Diesel Generator Set

    Minimum Rating
    1450 ekW
    Maximum Rating
    1600 ekW
    Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions
    Voltage
    220 to 13800 Volts
  • 3516 Diesel Generator Set

    Minimum Rating
    1600 kVA
    Maximum Rating
    2000 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption
    Voltage
    220 to 13800 Volts
  • 3516 Diesel Generator Set

    Minimum Rating
    1600 kVA
    Maximum Rating
    2000 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions
    Voltage
    400 to 415 Volts
  • 3516B (50 Hz) Generator Set

    Minimum Rating
    1750 kVA
    Maximum Rating
    2500 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions
    Voltage
    220 to 13800 Volts
  • 3516B (50 Hz) India Market Only

    Minimum Rating
    2000 kVA
    Maximum Rating
    2000 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption
    Voltage
    Voltage - Low (415 Volts), Medium and High Voltage
  • 3516B (50 Hz) with Upgradeable Package

    Minimum Rating
    1750 kVA
    Maximum Rating
    2500 kVA
    Emissions/Fuel Strategy
    Low fuel Consumption, Low Emissions
    Voltage
    220 to 4160 Volts
  • 3516B (60 Hz) with Upgradeable Package

    Minimum Rating
    1640 ekW
    Maximum Rating
    2250 ekW
    Emissions/Fuel Strategy
    Low fuel Consumption, Low Emissions
    Voltage
    220 to 4160 Volts
  • 3516B Generator Set

    Minimum Rating
    1750 kVA
    Maximum Rating
    2500 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions
    Voltage
    220 to 13800 Volts
  • 3516B Generator Set

    Minimum Rating
    2000 kVA
    Maximum Rating
    2500 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions
    Voltage
    400 to 11000 Volts
  • 3516B Generator Set

    Minimum Rating
    1640 ekW
    Maximum Rating
    2250 ekW
    Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions
    Voltage
    220 to 13800 Volts
  • 3516B Generator Set

    Minimum Rating
    1750 kVA
    Maximum Rating
    2275 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption
    Voltage
    220 to 11000 Volts
  • 3516B Generator Set

    Minimum Rating
    1640 ekW
    Maximum Rating
    1825 ekW
    Emissions/Fuel Strategy
    Low Fuel Consumption
    Voltage
    380 to 13800 Volts
  • 3516B Generator Set

    Minimum Rating
    1750 kVA
    Maximum Rating
    2250 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions
    Voltage
    400 to 11000 Volts
  • 3516C Generator Set

    Minimum Rating
    2500 kVA
    Maximum Rating
    2750 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions
    Voltage
    380 to 11000 volts
  • 3516C Generator Set

    Minimum Rating
    2250 kVA
    Maximum Rating
    3125 kVA
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)
    Voltage
    380 to 11000 Volts
  • 3516C Generator Set

    Minimum Rating
    1650 ekW
    Maximum Rating
    2500 ekW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards), Low Fuel Consumption
    Voltage
    220 to 13800 Volts
  • 3516C Tier 4 Final

    Minimum Rating
    1650 ekW
    Maximum Rating
    2500 ekW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Non-Emergency Stationary Genset
    Voltage
    480 to 13800 Volts
  • 3516E Generator Set

    Minimum Rating
    3000 kVA
    Maximum Rating
    3500 kVA
    Emissions/Fuel Strategy
    Tier 2 Equivalent, US EPA Stationary Emergency / Low NOx (1/2 TA Luft)
    Voltage
    380 to 11000 volts
  • 3516E Low Voltage Generator Set

    Minimum Rating
    2750 kVA
    Maximum Rating
    3000 kVA (3100 kVA without fan)
    Emissions/Fuel Strategy
    Low Fuel Consumption
    Voltage
    380 to 11000 volts
  • 3516E Low Voltage Generator Set

    Minimum Rating
    2500 eKW
    Maximum Rating
    2750 ekW
    Emissions/Fuel Strategy
    US EPA Stationary Emergency Use Only (Tier 2)
    Voltage
    416 to 13,800 Volts
  • 3606 Generator Set (Medium Speed)

    Minimum Rating
    1775 kVA
    Maximum Rating
    2688 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption
    Frequency
    50 Hz
  • 3606 Generator Set (Medium Speed)

    Minimum Rating
    1650 ekW
    Maximum Rating
    2000 ekW
    Emissions/Fuel Strategy
    Low Fuel Consumption
    Frequency
    60 Hz
  • 3608 Generator Set (Medium Speed)

    Minimum Rating
    1830 ekW
    Maximum Rating
    2660 ekW
    Emissions/Fuel Strategy
    Low Fuel Consumption
    Frequency
    60 Hz
  • 3608 Generator Set (Medium Speed)

    Minimum Rating
    2363 kVA
    Maximum Rating
    3575 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption
    Frequency
    50 Hz
  • 3612 Generator Set (Medium Speed)

    Minimum Rating
    3300 ekW
    Maximum Rating
    4000 ekW
    Emissions/Fuel Strategy
    Low Fuel Consumption
    Frequency
    60 Hz
  • 3612 Generator Set (Medium Speed)

    Minimum Rating
    4400 kVA
    Maximum Rating
    4850 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption
    Frequency
    50 Hz
  • 3616 Generator Set (Medium Speed)

    Minimum Rating
    3350 ekW
    Maximum Rating
    5320 ekW
    Emissions/Fuel Strategy
    Low Fuel Consumption
    Frequency
    60 Hz
  • 3616 Generator Set (Medium Speed)

    Minimum Rating
    4700 kVA
    Maximum Rating
    7520 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption
    Frequency
    50 Hz
  • ATC Contactor Based Bypass Isolation Automatic Transfer Switch

    Rating Range
    100 to 1200A
    Transfer Type
    Bypass Isolation
    Switch Type
    Contactor Based
    Control Power
    100-1200A 2-, 3-, 4-pole
  • ATC Contactor-Based Automatic Transfer Switch

    Rating Range
    40-1600A
    Transfer Type
    Open / Closed Transition
    Switch Type
    Contactor Based
    Control Power
    Wall Mount 40-600A 2 or 3 Pole
    Floor Standing 600A 4 Pole & 800-1200A 2, 3, or 4 Pole
  • ATC Molded Case Circuit Breaker & Molded Case Switch Automatic Transfer Switch

    Rating Range
    30-1000A
    Transfer Type
    Open transition
    Switch Type
    Molded Case
    Control Power
    30-1000A 2, 3, or 4 Pole, 100% Rated
  • ATC Power Breaker & Case Switch Automatic Transfer Switch

    Rating Range
    200 to 5000A
    Transfer Type
    Open Transition
    Switch Type
    Power Breaker
    Control Power
    Fixed Mount 200-3200A 2, 3, or 4 Pole
    Drawout 200-5000A 2-, 3-, 4-pole
  • ATC Power Breaker Bypass Isolation Open/Closed Transition Automatic Transfer Switch

    Rating Range
    200-5000A
    Transfer Type
    Bypass isolation, Closed transition
    Switch Type
    Power Breaker
    Control Power
    200-5000A, 2-, 3-, 4-pole
    100% rated Short
  • ATC Service Entrance Rated MCCB & Power Breaker Based ATS

    Rating Range
    30-5000A
    Transfer Type
    Open / Closed / Delayed
    Switch Type
    Molded Case and Power Breaker
    MCCB
    30-1000A 2, 3, or 4 Pole
  • ATC-100 CONTROLLER

    Rating Range
    120 to 480V, single phase and three phase @ 50/60 Hz
    Transfer Type
    Switch application dependent
    Switch Type
    Switch application dependent
    Input Control Voltage
    95 to 145 Vac 50/60 Hz
  • ATC-300+ CONTROLLER

    Rating Range
    120 to 600V, single phase and three phase @ 50/60 Hz
    Transfer Type
    Switch application dependent
    Switch Type
    Switch application dependent
    Input Control Voltage
    65 to 145 Vac 50/60 hZ
  • ATC-800 CONTROLLER

    Rating Range
    120 to 600V, single phase and three phase @ 50/60 Hz
    Transfer Type
    Switch application dependent
    Switch Type
    Switch application dependent
    Input Control Voltage
    120Vac (50/60 Hz) (operating range 65 to 160 Vac)
  • C1.1 Generator Set

    Minimum Rating
    8.0 ekW
    Maximum Rating
    8.8 ekW
    Emissions/Fuel Strategy
    R96/EUIIIa Equivalent
    Voltage
    110 to 480 Volts
  • C1.1 Generator Set

    Minimum Rating
    6.8 kVA
    Maximum Rating
    9.5 kVA
    Emissions/Fuel Strategy
    R96/EUIIIa Equivalent
    Voltage
    110 to 415 Volts
  • C1.5 Generator Set

    Minimum Rating
    12.0 ekW
    Maximum Rating
    13.2 ekW
    Emissions/Fuel Strategy
    R96/EUIIIa Equivalent
    Voltage
    110 to 415 Volts
  • C1.5 Generator Set

    Minimum Rating
    10.0 kVA
    Maximum Rating
    13.5 kVA
    Emissions/Fuel Strategy
    R96/EUIIIa Equivalent
    Voltage
    110 to 415 Volts
  • C13 (50 Hz) India Market Only

    Minimum Rating
    400 kVA
    Maximum Rating
    400 kVA
    Emissions/Fuel Strategy
    India CPCB/MoEF
    Voltage
    415 Volts
  • C13 (50 Hz) China Non Road

    Minimum Rating
    350 kVA
    Maximum Rating
    450 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption, R96/EUIIIa Equivalent Nonroad Emission Standards, China Nonroad III Emission Standards
    Voltage
    380 to 415 Volts
  • C13 Generator Set

    Minimum Rating
    320 ekW
    Maximum Rating
    400 ekW
    Emissions/Fuel Strategy
    Low Fuel Consumption
    Voltage
    380 to 415 Volts
  • C13 Generator Set

    Minimum Rating
    350 kVA
    Maximum Rating
    450 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption, R96/EUIIIa Equivalent Nonroad Emission Standards
    Voltage
    380 to 415 Volts
  • C13 Generator Set

    Minimum Rating
    320 ekW
    Maximum Rating
    400 ekW
    Emissions/Fuel Strategy
    EPA Stationary Emergency Use
    Voltage
    208 to 600 Volts
  • C15 (50 Hz) India Market Only

    Minimum Rating
    500 kVA
    Maximum Rating
    500 kVA
    Emissions/Fuel Strategy
    India CPCB/MoEF
    Voltage
    415 Volts
  • C15 (50 Hz) China Non Road

    Minimum Rating
    365 kVA
    Maximum Rating
    550 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 or Tier 3 Nonroad Equivalent Emission Standards), EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards
    Voltage
    208 to 600 Volts
  • C15 Generator Set

    Minimum Rating
    320 ekW
    Maximum Rating
    500 ekW
    Emissions/Fuel Strategy
    Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 or Tier 3 Nonroad Equivalent Emission Standards), EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards
    Voltage
    208 to 600 Volts
  • C15 Generator Set

    Minimum Rating
    320 ekW
    Maximum Rating
    500 ekW
    Emissions/Fuel Strategy
    Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 or Tier 3 Nonroad Equivalent Emission Standards), EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards
    Voltage
    208 to 600 Volts
  • C15 Generator Set

    Minimum Rating
    365 kVA
    Maximum Rating
    550 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 or Tier 3 Nonroad Equivalent Emission Standards), EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards
    Voltage
    208 to 600 Volts
  • C175-16 Generator Set

    Minimum Rating
    2500 kVA
    Maximum Rating
    3100 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)
    Voltage
    220 to 13800 Volts
  • C175-16 Generator Set

    Minimum Rating
    2500 ekW
    Maximum Rating
    3100 ekW
    Emissions/Fuel Strategy
    Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)
    Voltage
    220 to 13800 Volts
  • C175-16 Tier 4 Final

    Minimum Rating
    2500 ekW
    Maximum Rating
    3100 ekW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Non-Emergency Stationary Genset
    Voltage
    480 to 13800 Volts
  • C175-20

    Minimum Rating
    3150 kVA
    Maximum Rating
    4000 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption, U.S. EPA Stationary Emergency Use Only
    Voltage
    3300 to 13800 Volts
  • C175-20

    Minimum Rating
    3150 ekW
    Maximum Rating
    4000 ekW
    Emissions/Fuel Strategy
    Low Fuel Consumption, U.S. EPA Stationary Emergency Use Only
    Voltage
    3300 to 13800 Volts
  • C18 (50 Hz) India Market Only

    Minimum Rating
    600 kVA
    Maximum Rating
    600 kVA
    Emissions/Fuel Strategy
    India CPCB/MoEF
    Voltage
    415 Volts
  • C18 Generator Set

    Minimum Rating
    455 ekW
    Maximum Rating
    600 ekW
    Emissions/Fuel Strategy
    Low Fuel Consumption
    Voltage
    208 to 600 Volts
  • C18 Generator Set

    Minimum Rating
    500 ekW
    Maximum Rating
    600 ekW
    Emissions/Fuel Strategy
    Low Fuel Consumption
    Voltage
    220 to 380 Volts
  • C18 Generator Set

    Minimum Rating
    550 kVA
    Maximum Rating
    715 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards), China Nonroad III Emission Standards
    Voltage
    208 to 600 Volts
  • C18 Generator Set

    Minimum Rating
    455 ekW
    Maximum Rating
    600 ekW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)
    Voltage
    208 to 600 Volts
  • C18 Generator Set

    Minimum Rating
    500 ekW
    Maximum Rating
    750 ekW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)
    Voltage
    208 to 600 Volts
  • C18 Generator Set

    Minimum Rating
    550 kVA
    Maximum Rating
    850 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards), China Nonroad III Emission Standards
    Voltage
    208 to 600 Volts
  • C18 Generator Set

    Minimum Rating
    550 kVA
    Maximum Rating
    715 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards), EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards
    Voltage
    208 to 600 Volts
  • C18 Generator Set

    Minimum Rating
    455 ekW
    Maximum Rating
    500 ekW
    Emissions/Fuel Strategy
    U.S. EPA Tier 4 Final
    Voltage
    480 Volts
  • C2.2 Generator Set

    Minimum Rating
    15.5 ekW
    Maximum Rating
    20.0 ekW
    Emissions/Fuel Strategy
    R96/EUIIIa Equivalent
    Voltage
    110 to 415 Volts
  • C2.2 Generator Set

    Minimum Rating
    13.0 kVA
    Maximum Rating
    22.0 kVA
    Emissions/Fuel Strategy
    R96/EUIIIa Equivalent
    Voltage
    110 to 415 Volts
  • C27 Generator Set

    Minimum Rating
    680 ekW
    Maximum Rating
    800 ekW
    Emissions/Fuel Strategy
    Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)
    Voltage
    208 to 600 Volts
  • C3.3 Generator Set

    Minimum Rating
    24.0 kVA
    Maximum Rating
    65.0 kVA
    Emissions/Fuel Strategy
    Non Regulated, EU Stage II and R96/EUIIIa Equivalent
    Voltage
    110 to 480 Volts
  • C3.3 Generator Set

    Minimum Rating
    27.0 ekW
    Maximum Rating
    60.0 ekW
    Emissions/Fuel Strategy
    Non Regulated, EU Stage II and R96/EUIIIa Equivalent
    Voltage
    110 to 480 Volts
  • C32 (50 Hz) India Market Only

    Minimum Rating
    1010 kVA
    Maximum Rating
    1250 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption
    Voltage
    415 Vots
  • C32 (50 Hz) with Upgradeable Packaging

    Minimum Rating
    910 kVA
    Maximum Rating
    1500 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions
    Voltage
    220 to 4160 Volts
  • C32 (60 Hz)

    Minimum Rating
    830 ekW
    Maximum Rating
    1250 ekW
    Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions, EPA Certified for Stationary Emergency Application (Emits Equivalent U.S. EPA Tier 2 Nonroad Standards)
    Voltage
    220 to 4160 Volts
  • C32 (60 Hz) with Upgradeable Packaging

    Minimum Rating
    830 ekW
    Maximum Rating
    1000 eKW
    Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions
    Voltage
    220 to 4160 Volts
  • C32 Generator Set

    Minimum Rating
    910 kVA
    Maximum Rating
    1500 kVA
    Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions, EPA Certified for Stationary Emergency Application (Emits Equivalent U.S. EPA Tier 2 Nonroad Standards)
    Voltage
    220 to 4160 Volts
  • C4.4 Generator Set

    Minimum Rating
    36 ekW
    Maximum Rating
    60 ekW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Use Only (Tier 3 Nonroad Equivalent Emission Standards)
    Voltage
    208 to 600 Volts
  • C4.4 Generator Set

    Minimum Rating
    72 ekW
    Maximum Rating
    100 ekW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Use Only (Tier 3 Nonroad Equivalent Emission Standards)
    Voltage
    110 to 480 Volts
  • C4.4 Generator Set

    Minimum Rating
    36 ekW
    Maximum Rating
    100 ekW
    Emissions/Fuel Strategy
    Non Regulated, EU Stage II
    Voltage
    220 to 480 Volts
  • C4.4 Generator Set

    Minimum Rating
    50 kVA
    Maximum Rating
    110 kVA
    Emissions/Fuel Strategy
    Non Regulated, EU Stage II and R96/EUIIIa Equivalent
    Voltage
    110 to 480 Volts
  • C7.1 ACERT

    Minimum Rating
    120 ekW
    Maximum Rating
    175 ekW
    Emissions/Fuel Strategy
    Non Regulated
    Voltage
    208 to 480 Volts
  • C7.1 ACERT

    Minimum Rating
    135 kVA
    Maximum Rating
    218 kVA
    Emissions/Fuel Strategy
    Non Regulated, EU Stage IIIA
    Voltage
    110 to 480 Volts
  • C7.1 Generator Set

    Minimum Rating
    114 ekW
    Maximum Rating
    200 ekW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Use Only ( Tier 3 Nonroad Equivalent Emission Standards)
    Voltage
    208 to 480 Volts
  • C9 Generator Set

    Minimum Rating
    230 kVA
    Maximum Rating
    330 kVA
    Emissions/Fuel Strategy
    EU Stage IIIA, Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use only ( Tier 3 Nonroad Equivalent Emission Standards)
    Voltage
    220 to 480 Volts
  • C9 Generator Set

    Minimum Rating
    180 ekW
    Maximum Rating
    300 ekW
    Emissions/Fuel Strategy
    Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use only ( Tier 3 Nonroad Equivalent Emission Standards)
    Voltage
    220 to 480 Volts
  • C9 Generator Set

    Minimum Rating
    180 ekW
    Maximum Rating
    300 ekW
    Emissions/Fuel Strategy
    EU Stage IIIA, Low Fuel Consumption
    Voltage
    220 to 480 Volts
  • Cat Customizable Switchgear and Controls

    Configuration
    Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc
    Modes of Operation
    All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical pow
    Application
    LV and MV ( 208V - 38 kV) 50 / 60 Hz
    ANSI Protective Devices
    Per customer specification
  • Cat EGP Switchgear

    Configuration
    Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applications
    Modes of Operation
    Multi-unit Island and multi-unit standby mode with optional redundant controls and components.
    Application
    LV and MV (208V - 38 kV)
    ANSI Protective Devices
    15/25, 27/59, 81 O/U, 32, 40, 50, 51
  • Cat EGP Switchgear

    Configuration
    Remote monitoring and control for up to 8 generator sets via high-speed network. Enables paralleling a group of EMCP 4.4 equipped generator sets to a single utility source.
    Modes of Operation
    Emergency standby, island, utility paralleling
    Application
    LV and MV (208V - 38 kV)
    ANSI Protective Devices
    15/25, 27/59, 81 O/U, 32, 40, 50, 51
  • Cat PVC365 MP Photovoltaic Module

    Application
    Compatible with 1000V and 1500V plant architectures
    Module Type
    Mono crystalline PERC
    Nominal Power
    365W per panel
  • Cat Switchgear

    Configuration
    IP4X
    Operating Temperature
    35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)
    Standard Widths
    600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.
    Application
    LV 380…480 VAC, 50 Hz, 3-Phase.
  • Cat XLM Switchgear

    Configuration
    Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie, utility and load breakers for utility paralleling applications
    Modes of Operation
    Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power
    Application
    LV and MV ( 208V - 38 kV
    ANSI Protective Devices
    15/25, 27/59, 81 O/U, 32, 40, 50, 51
  • CG132B-12 Gas Generator Set

    Maximum Continuous Rating
    600 kW
    Fuel Type
    Natural Gas, Biogas
    Maximum Electrical Efficiency
    43.3% / 42.4%
    Maximum Standby Rating
    600 kW
  • CG132B-8 Gas Generator Set

    Maximum Continuous Rating
    400 ekW
    Fuel Type
    Natural Gas, Biogas, Coal Gas
    Maximum Electrical Efficiency
    43.1% / 42.1%
    Frequency
    50 / 60 Hz
  • CG170 Gas Generator Set

    Maximum Continuous Rating
    1560 ekW
    Fuel Type
    Natural Gas, Biogas, Coal Gas
    Maximum Electrical Efficiency
    43.3%
    Frequency
    50 or 60 Hz
  • CG170-12 Gas Generator Set

    Maximum Continuous Rating
    1200 ekW
    Fuel Type
    Natural Gas, Biogas, Coal Gas
    Maximum Electrical Efficiency
    43.40%
    Frequency
    50 or 60 Hz
  • CG170-20 Gas Generator Set

    Maximum Continuous Rating
    2000 ekW
    Fuel Type
    Natural Gas, Biogas, Coal Gas
    Maximum Electrical Efficiency
    43.7%
    Maximum Standby Rating
    2000
  • CG170-20B Gas Generator Set

    Maximum Continuous Rating
    2300 ekW
    Fuel Type
    Natural Gas, Biogas, Coal Gas
    Maximum Electrical Efficiency
    45.00%
    Maximum Standby Rating
    2300
  • CG260 Gas Generator Set

    Maximum Continuous Rating
    3000 ekW
    Fuel Type
    Natural Gas, Coal Gas
    Maximum Electrical Efficiency
    43.9%
    Maximum Standby Rating
    3333 ekW
  • CG260-16 Gas Generator Set

    Maximum Continuous Rating
    4000 ekW
    Fuel Type
    Natural Gas, Biogas, Coal Gas, Associated Gas, Synthesis Gas
    Maximum Electrical Efficiency
    44.6%
    Maximum Standby Rating
    4500 ekW
  • CM20C Generator Set

    Minimum Rating
    985 kWe
    Maximum Rating
    1650 kWe
    Emissions/Fuel Strategy
    World bank (WB) emission certification stage 1 and 2, Post-emission treatment systems for lower emission requirements available
    Voltage
    3000 to 13800 Volts
  • CM25C Generator Set

    Minimum Rating
    1735 kWe
    Maximum Rating
    2600 kWe
    Emissions/Fuel Strategy
    World bank (WB) emission certification stage 1 and 2, Post-emission treatment systems for lower emission requirements available
    Voltage
    3000 to 13800 Volts
  • CM25E Generator Set

    Minimum Rating
    1940 kWe
    Maximum Rating
    2910 kWe
    Emissions/Fuel Strategy
    World bank (WB) emission certification stage 1 and 2, Post-emission treatment systems for lower emission requirements available
    Voltage
    3000 to 13800 Volts
  • CM32C (Inline) Generator Set

    Minimum Rating
    2780 kWe
    Maximum Rating
    4170 kWe
    Emissions/Fuel Strategy
    World bank (WB) emission certification stage 1 and 2, Post-emission treatment systems for lower emission requirements available
    Voltage
    3000 to 13800 Volts
  • CM32C (V-Type) Generator Set

    Minimum Rating
    5580 kWe
    Maximum Rating
    7840 kWe
    Emissions/Fuel Strategy
    World bank (WB) emission certification stage 1 and 2, Post-emission treatment systems for lower emission requirements available
    Voltage
    3000 to 13800 Volts
  • CM32E

    Minimum Rating
    3085 kWe
    Maximum Rating
    4630 kWe
    Emissions/Fuel Strategy
    World bank (WB) emission certification stage 1 and 2, Post-emission treatment systems for lower emission requirements available
    Voltage
    3000 to 13800 Volts
  • CM43C (Inline)

    Minimum Rating
    5520 kWe
    Maximum Rating
    8290 kWe
    Emissions/Fuel Strategy
    World bank (WB) emission certification stage 1 and 2, Post-emission treatment systems for lower emission requirements available
    Voltage
    3000 to 13800 Volts
  • CM43C (V-Type)

    Minimum Rating
    11170 kWe
    Maximum Rating
    14890 kWe
    Emissions/Fuel Strategy
    World bank (WB) emission certification stage 1 and 2, Post-emission treatment systems for lower emission requirements available
    Voltage
    3000 to 13800 Volts
  • CM46DF (Inline)

    Minimum Rating
    5290 kWe
    Maximum Rating
    7930 kWe
    Emissions/Fuel Strategy
    World bank (WB) emission certification stage 1 and 2, Technische Anleitung (TA) Luft 2002 (only gas), Post-emission treatment systems for lower emission requirements available
    Voltage
    3000 to 13800 Volts
  • CM46DF (V-Type)

    Minimum Rating
    10580 kWe
    Maximum Rating
    14110 kWe
    Emissions/Fuel Strategy
    World bank (WB) emission certification stage 1 and 2, Technische Anleitung (TA) Luft 2002 (only gas), Post-emission treatment systems for lower emission requirements available
    Voltage
    3000 to 13800 Volts
  • CTE Series Automatic Transfer Switch

    Rating Range
    40-4000A
    Transfer Type
    Open / Closed / 4 position switch
    Switch Type
    Contactor Based
    Control Power
    40 to 4000 amperes, 2,3 or 4 poles
  • CTG Series Automatic Transfer Switch

    Rating Range
    40-3000A
    Transfer Type
    Open transition
    Switch Type
    Contactor based
  • CTGSE & CTGDSE Series Service Rated Entrance Rated Automatic Transfer Switch

    Rating Range
    40-3000A
    Transfer Type
    Open Transition with Service Entrance
    Switch Type
    Contactor Based
  • CTS Series Automatic Transfer Switch

    Rating Range
    40 to 4000A
    Transfer Type
    Open transition
    Switch Type
    Contactor Based
    Control Power
    40 to 4000 amperes, 2, 3 or 4 Poles
  • CTSM and CTGM Series Manual Transfer Switches

    Rating Range
    40-4000A
    Transfer Type
    Open / Manual
    Switch Type
    Contactor Based
  • CTX Series Automatic Transfer Switch

    Rating Range
    40-400A
    Transfer Type
    Open transition
    Switch Type
    Contactor Based
  • DG100-2 (3 Phase)

    Voltage
    480 Volts
    Frequency
    60 Hz
    Natural Gas Rating
    100 ekW / 92 ekW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
  • DG100-2S (Single Phase)

    Voltage
    240 Volts
    Frequency
    60 Hz
    Natural Gas Rating
    100 ekW / 90 ekW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
  • DG125-2 (3 Phase)

    Voltage
    480 Volts
    Frequency
    60 Hz
    Natural Gas Rating
    125 ekW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
  • DG150-2 (3 Phase)

    Voltage
    480 Volts
    Frequency
    60 Hz
    Natural Gas Rating
    150 ekW / 140 ekW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
  • DG175-2 (3 phase)

    Frequency
    60 Hz
    Natural Gas Rating
    175 eKW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
    Engine Model
    G14.2L Spark Ignited
  • DG175-2 (Single-phase)

    Frequency
    60 Hz
    Natural Gas Rating
    175 eKW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
    Engine Model
    G14.2L Inline 6, 4 cycle, Spark Ignited
  • DG200-2 (3 phase)

    Frequency
    60 Hz
    Natural Gas Rating
    200 eKW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
    Engine Model
    14.2 L, Inline 6, 4 Cycle, Spark - Ignited
  • DG200-2S (Single-phase)

    Frequency
    60 Hz
    Natural Gas Rating
    250 eKW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
    Engine Model
    14.2 L Spark - Ignited
  • DG230-2 (3 phase)

    Frequency
    60 Hz
    Natural Gas Rating
    230 eKW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
    Speed
    1800 rpm
  • DG250-2 (3 phase)

    Frequency
    60 Hz
    Natural Gas Rating
    250 eKW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
    Displacement
    864.7in³
  • DG275-2 (3 phase)

    Frequency
    60 Hz
    Natural Gas Rating
    275 eKW
    Speed
    1800 rpm
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
  • DG300-2 (3 phase)

    Frequency
    60 Hz
    Natural Gas Rating
    300 eKW
    Speed
    1800 rpm
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
  • DG350-2 (Single-phase)

    Frequency
    60 Hz
    Natural Gas Rating
    350 eKW
    Speed
    1800 rpm
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
  • DG400-2 (Three phase)

    Voltage
    120/208, 120/240, 277/480, 346/600 VAC
    Frequency
    60 Hz
    Natural Gas Rating
    400 ekW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
  • DG450-2 (Single-phase)

    Voltage
    120/208, 120/240, 277/480, 346/600 VAC
    Frequency
    60 Hz
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
    Engine Model
    G21.9L V12, 4-Cycle, Spark -Ignited
  • DG50-2 (3 Phase)

    Voltage
    480 Volts
    Frequency
    60 Hz
    Natural Gas Rating
    50 ekW / 50 ekW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
  • DG50-2 (Single Phase)

    Voltage
    240 Volts
    Frequency
    60 Hz
    Natural Gas Rating
    50 ekW / 50 ekW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
  • DG60-2 (3 Phase)

    Voltage
    480 Volts
    Frequency
    60 Hz
    Natural Gas Rating
    60 ekW / 60 ekW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
  • DG60-2 (Single Phase)

    Voltage
    240 Volts
    Frequency
    60 Hz
    Natural Gas Rating
    60 ekW / 60 ekW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
  • DG80-2 (3 Phase)

    Voltage
    480 Volts
    Frequency
    60 Hz
    Natural Gas Rating
    80 ekW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
  • DG80-2 (Single Phase)

    Voltage
    240 Volts
    Frequency
    60 Hz
    Natural Gas Rating
    80 ekW
    Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
  • Emergency Transfer Load manager

    Configuration
    Wall mounted paralleling control system that monitors and controls a single generator and a single utility.
    Modes of Operation
    Utility Import, Export, and base load operations, Peak shaving, and Emergency Standby. Closed Transition to/from Generator Power
    Application
    LV and MV (208V-32kV)
    ANSI Protective Devices
    15/25. 27/59, 81 O/U, 32, 40, 50, 51
  • Energy Time Shift Module

    Application
    Time shifting of renewable energy, Grid forming, Grid firming/grid stabilization, Renewable smoothing, Peak shaving, Grid firming/grid stabilization, Facility backup, Spinning reserve
    Rated Power
    250 - 1000 kW
  • Energy Time Shift Module

    Application
    The Cat® Microgrid Master Controller integrates the photovoltaic (PV) system, generator set, and energy storage system to maximize penetration from renewable energy sources and system reliability.
  • Engine Paralleling and Integration Control (EPIC)

    Configuration
    Remote modular paralleling control system (Master Control Panel for the first 2 generator sets and optional tie breaker, separate add-on control panels for up to 8 additional generator sets, utility paralleling control, and distribution control)
    Modes of Operation
    Emergency Standby with redundant master control, Utility paralleling, peak shaving, and closed transition to/from Generator Power (with optional utility control panel)
    Application
    LV and MV (208V-27kV)
    ANSI Protective Devices
    15/25. 27/59, 81 O/U, 32, 40, 90 (Industrial Grade)
  • G175LG6 Gas Generator Set

    Standby
    175 kW (219 kVA) 60hz
    Fuel Type
    Natural Gas
    Prime
    158 kW (197 kVA) 60hz
    Frequency
    60 Hz
  • G200LG6 Gas Generator Set

    Standby
    200 kW (250 kVA) 60hz
    Fuel Type
    Natural Gas
    Prime
    180 kW (225 kVA) 60hz
    Frequency
    60 Hz
  • G230LG6 Gas Generator Set

    Standby
    230 kW (288 kVA) 60hz
    Fuel Type
    Natural Gas
    Prime
    207 kW (259 kVA) 60hz
    Frequency
    60 Hz
  • G275LG6 Gas Generator Set

    Standby
    275 kW (344 kVA) 60hz
    Fuel Type
    Natural Gas
    Prime
    247 kW (309 kVA) 60hz
    Frequency
    60 Hz
  • G300LG6 Gas Generator Set

    Standby
    300 kW (375 kVA) 60hz
    Fuel Type
    Natural Gas
    Prime
    270 kW (338 kVA) 60hz
    Frequency
    60 Hz
  • G3406 Gas Generator Set

    Maximum Continuous Rating
    235 ekW
    Fuel Type
    Natural Gas, Biogas, Field Gas, Propane
    Maximum Electrical Efficiency
    37.30%
    Maximum Standby Rating
    260
  • G3412 Gas Generator Set

    Maximum Continuous Rating
    453 ekW
    Fuel Type
    Natural Gas, Biogas, Field Gas, Propane
    Maximum Electrical Efficiency
    37.30%
    Maximum Standby Rating
    500
  • G3512 1000kW Gas Generator Set

    Gas Standby Rating
    1000 ekW
    Fuel Type
    Natural Gas
    Emissions/Fuel Strategy
    U.S. EPA Certified for Non-Emergency Stationary Genset
    RPM
    1800 rpm
  • G3512 750kW Gas Generator Set

    Gas Standby Rating
    750 ekW
    Fuel Type
    Natural Gas
    Emissions/Fuel Strategy
    U.S. EPA Certified for Non-Emergency Stationary Genset
    RPM
    1800 rpm
  • G3512E Gas Generator Set

    Maximum Continuous Rating
    1000 ekW
    Fuel Type
    Natural Gas
    Maximum Electrical Efficiency
    42.2%
    Maximum Standby Rating
    -
  • G3516C Gas Generator Set

    Maximum Continuous Rating
    1675 ekW
    Fuel Type
    Natural Gas
    Maximum Electrical Efficiency
    40.00%
    Maximum Standby Rating
    1500
  • G3520C Gas Generator

    Maximum Continuous Rating
    2082
    Fuel Type
    Natural Gas, Biogas, Coal Gas
    Maximum Electrical Efficiency
    40.10%
    Maximum Standby Rating
    2000
  • G3520E Gas Generator Set

    Maximum Continuous Rating
    2022
    Fuel Type
    Natural Gas
    Maximum Electrical Efficiency
    41.50%
    Maximum Standby Rating
    2022
  • G3520H Gas Generator

    Maximum Continuous Rating
    2519 / 2500 ekW
    Fuel Type
    Natural Gas
    Maximum Electrical Efficiency
    45.30%
    Frequency
    50 / 60 Hz
  • G3550 2000kW Gas Generator Set

    Gas Standby Rating
    2000 ekW
    Fuel Type
    Natural Gas
    Frequency
    60 Hz
    RPM
    1800 rpm
  • G3550 2500kW Gas Generator Set

    Gas Standby Rating
    2500 ekW
    Fuel Type
    Natural Gas
    Frequency
    60 Hz
    RPM
    1800 rpm
  • Gas Generator CG132B-16

    Maximum Continuous Rating
    1000 ekW
    Fuel Type
    Natural Gas
    Maximum Electrical Efficiency
    41.0%
    Frequency
    50 Hz
  • Gas Generator CG132B-16

    Maximum Continuous Rating
    800 kW
    Fuel Type
    Natural Gas, Biogas
    Maximum Electrical Efficiency
    43.5% / 42.6%
    Maximum Standby Rating
    800 kW
  • Gas Generator G3512H

    Maximum Continuous Rating
    1515 ekW / 1505 ekW
    Fuel Type
    Natural Gas
    Maximum Electrical Efficiency
    44.90%
    Maximum Standby Rating
    1515 ekW / 1505 ekW
  • Gas Generator G3516A

    Maximum Continuous Rating
    1041 ekW
    Fuel Type
    Natural Gas, Biogas, Coal Gas
    Maximum Electrical Efficiency
    36.40%
    Maximum Standby Rating
    1000 kw
  • Gas Generator G3516B

    Maximum Continuous Rating
    1300 ekW
    Fuel Type
    Natural Gas
    Maximum Electrical Efficiency
    35.60%
    Maximum Standby Rating
    1300 kW
  • Gas Generator G3516H

    Maximum Continuous Rating
    2027 / 2007 ekW
    Fuel Type
    Natural Gas
    Maximum Electrical Efficiency
    44.70%
    Frequency
    50 / 60 Hz
  • GCM34

    Voltage
    3-13.8 kV
    Specific Energy Consumption Up To
    6971Btu/kWh
    Bore
    13.39in
    Height
    201in
  • GEUG16-1 Gas Generator Set

    Standby
    250 kW (313 kVA) 60hz
    Fuel Type
    Natural Gas
    Prime
    225 kW (281 kVA) 60hz
    Frequency
    60 Hz
  • Grid Stability Module

    Application
    Renewable smoothing, Generator set transient assist, Grid firming/grid stabilization, Facility backup, Spinning reserve
    Rated Power
    375 - 1875 kW
  • MX150 Microprocessor Controller

    Rating Range
    Switch Dependent
    Transfer Type
    Application Dependent
    Switch Type
    Application Dependent
    Undervoltage Dropout for Source 1 and Source 2
    75-98% of nominal
  • MX250 Microprocessor Controller

    Rating Range
    Switch Dependent
    Transfer Type
    Application Dependent
    Switch Type
    Application Dependent
    Undervoltage Dropout for Source 1 and Source 2
    75-98% of nominal
  • MX350 Controller

    Rating Range
    Switch Dependent
    Transfer Type
    Application Dependent
    Switch Type
    Application Dependent
    Source Sensing
    120 - 690 VAC +/- 1% of nominal voltage (+/- .05 Hz, +/-.5 A)
  • Photovoltaic (PV) Module PVT115

    Application
    Compatible with 1000V and 1500V plant architectures
    Module Type
    Shingled mono crystalline PERC
    Nominal Power
    395W per panel
  • Photovoltaic (PV) Module PVT117

    Application
    Compatible with 1000V and 1500V plant architectures
    Module Type
    Advanced thin film solar
    Nominal Power
    117.5W per panel
  • XG135 – Natural Gas

    Rating
    135 ekW (170 kVA) Continuous
    Frequency
    60Hz
    Voltage
    208 - 480 V
    Engine
    CAT G3306 TA Gas Engine
  • XG400 – Natural Gas

    Rating
    400 ekW (500 kVA) Continuous
    Frequency
    60Hz
    Voltage
    208 - 600 V
    Engine
    CAT CG137-12 TA Gas Engine
  • XQ125 Rental Power

    Rating Prime
    100 ekW (125 kVA)
    Frequency
    60 Hz
    Voltage
    120 - 480V
    Rating Standby
    110 ekW (137 kVA)
  • XQ1475G

    Rating
    1475 ekW Continuous
    Frequency
    50/60 Hz
    Voltage
    230 - 480 V
    Engine
    Cat G3516C Low Emissions Gas Engine
  • XQ2000

    Rating
    2000 ekW (2500 kVA) Standby
    Frequency
    50/60 Hz
    Voltage
    230 - 480 V
    Engine
    3516 Tier II ATAAC
  • XQ2000

    Rating (1)
    1400 ekW (1750 kVA) Continuous
    Rating (2)
    1600 ekW (2000 kVA) Prime
    Frequency
    50 Hz
    Voltage
    240 - 480 V
  • XQ230 Rental Power

    Rating Prime
    182 ekW (228 kVA)
    Frequency
    60 Hz
    Voltage
    120 - 480V
    Rating Standby
    200 ekW (250 kVA)
  • XQ35

    Rating Prime
    27 ekW (35 kVA)
    Frequency
    60 Hz
    Voltage
    120 - 480V
    Rating Standby
    30 ekW (38 kVA)
  • XQ425

    Rating Prime
    340 ekW (425 kVA)
    Frequency
    50/60 Hz
    Voltage
    120 - 480V
    Rating Standby
    375 ekW (469 kVA)
  • XQ570

    Rating Prime
    455 ekW (568 kVA)
    Frequency
    60 Hz
    Voltage
    120 - 480V
    Rating Standby
    500 ekW (625 kVA)
  • XQ60

    Rating Prime
    47.5 ekW (60 kVA)
    Frequency
    60 Hz
    Voltage
    120 - 480V
    Engine
    C3.4B
  • XQC1200

    Rating
    1150kW (1438 kVA) Continuous
    Frequency
    50/60 Hz
    Voltage
    230 - 480 V
    Engine
    Cat 3512C-HD heavy duty diesel engine
  • XQC1600

    Rating
    1515 ekW (1893 kVA) Continuous
    Frequency
    50/60 Hz
    Voltage
    230 - 480 V
    Engine
    CAT 3516C-HD DIESEL ENGINE
  • XQE20

    Prime Rating
    20 kVA (16 kW) Prime
    Frequency
    50/60 Hz
    Voltage
    220 - 415V
    Standby Run Time (Full Load)
    7.3 Hours
  • XQE30

    Prime Rating
    30 kVA (24 kW) Prime
    Frequency
    50/60 Hz
    Voltage
    220 - 415V
    Standby Run Time (Full Load)
    19.3 Hours
  • XQE60

    Prime Rating
    60 kVA (48 kW) Prime
    Frequency
    50/60 Hz
    Voltage
    220 - 415V
    Standby Run Time (Full Load)
    38.4 Hours
  • XQP100

    Rating Prime
    100 kVA
    Frequency
    50/60 Hz
    Voltage
    127 - 480 V
    Engine
    C4.4 Diesel Engine or Cat C4.4 ACERT Diesel Engine
  • XQP1100 Rental Generator Set

    Rating Prime
    1100 kVA
    Frequency
    50/60 Hz
    Voltage
    127 - 480 V
    Engine
    C32 Diesel Engine
  • XQP150

    Rating Prime
    150 kVA
    Frequency
    50/60 Hz
    Voltage
    127 - 480 V
    Engine
    C7.1 Diesel Engine or C7.1 ACERT Diesel Engine
  • XQP275

    Rating Prime
    275 kVA
    Frequency
    50/60 Hz
    Voltage
    127 - 480 V
    Engine
    Cat C9 ACERT Diesel Engine
  • XQP30 – Diesel

    Rating Prime
    30 kVa
    Frequency
    50/60 Hz
    Voltage
    127 - 480 V
    Engine
    Cat C3.3 Diesel Engine
  • XQP300

    Rating Prime
    300 kVA
    Frequency
    50/60 Hz
    Voltage
    127 - 480 V
    Engine
    Cat C9 ACERT Diesel Engine
  • XQP500

    Rating Prime
    500 kVA
    Frequency
    50/60 Hz
    Voltage
    127 - 480 V
    Engine
    C15 ACERT Diesel Engine
  • XQP60

    Rating Prime
    60 kVA
    Frequency
    50/60 Hz
    Voltage
    127 - 480 V
    Engine
    Cat C4.4 Diesel Engine