3512B Diesel Generator Set
At a Glance
Standby Rating
1500/1400 ekW
|
Prime Power Rating
1360/1275 ekW
|
Emissions/Fuel Strategy
Low Fuel, Low Emissions
|
Voltage
380 to 13800 Volts
|
Request a Quote
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
+
-
Standby Rating |
1500/1400 ekW |
Prime Power Rating |
1360/1275 ekW |
Emissions/Fuel Strategy |
Low Fuel, Low Emissions |
Voltage |
380 to 13800 Volts |
Frequency |
60 Hz |
Speed |
1800 rpm |
Duty Cycle |
Standby, Mission Critical, Prime, Continuous |
Maximum Rating |
1500 ekW |
Minimum Rating |
1230 ekW |
Engine Specifications
+
-
Engine Model |
3512B TA, V-12, 4-Stroke Water-Cooled Diesel |
Bore |
6.69in |
Stroke |
7.48in |
Displacement |
3573.55in³ |
Compression Ratio |
14.0:1 Std 15.5:1 HD |
Aspiration |
TA |
Fuel System |
Electronic Unit Injection |
Governor Type |
ADEM™ A3 |
Generator Set Dimensions
+
-
Length - Maximum |
221.9in |
Width - Maximum |
90in |
Height - Maximum |
93.2in |
Dry Weight - Genset (minimum) |
24430lb |
Dry Weight - Genset (maximum) |
25090lb |
Standard Equipment:
Air Inlet System
+
-
-
Air cleaner; single element canister type with service indicator
Exhaust System
+
-
-
Exhaust flange outlet
-
Dry exhaust manifold
-
Flanged faced outlet(s)
Generator
+
-
-
IP23 Protection
-
Matched to the performance and output characteristics of Cat engines
Control System
+
-
-
Alarm acknowledge
-
kW-hr (total)
-
Lamp test
-
Over/under voltage (27 / 59)
-
Digital indication for:
-
DC volts
-
PLC functionality
-
Speed adjust
-
4 Programmable relay outputs (Form A)�
-
Text alarm/event descriptions
-
Warning/shutdown with common LED indication of shutdowns for:
-
Engine cycle crank
-
Emergency stop
-
Auto/start/stop control
-
RPM
-
Reverse power (kW) (32)
-
True RMS AC metering, 3-phase, +/-2% accuracy
-
Accessory module data link
-
Low coolant level
-
kVAr-hr (total)
-
kVAr (per phase, average & percent)
-
1 Programmable relay outputs (Form C)
-
Over/under frequency (81 o/u)
-
Low oil pressure
-
Amps (per phase & average)
-
Failure to start (overcrank)
-
EMCP 4.2B
-
Controls:
-
High coolant temperature
-
Communications
-
Number of I/O varies on options selected
-
24 Volt DC operation
-
Engine cool-down timer
-
Low coolant temperature
-
Generator phase sequence
-
Frequency (Hz)
-
Volts (L-L & L-N)
-
Reverse reactive power (kVAr) (32RV)
-
Oil pressure (psi, kPa or bar)
-
Customizable screens
-
Generator set packages include Caterpillar's voltage
regulator (IVR). IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min max exciter. Limiter and exciter diode monitor
-
Load histogram feature
-
1 Programmable digital outputs
-
Customer data link (Modbus RTU)
-
Overspeed
-
Environmental sealed front face
-
Coolant temperature
-
kW (per phase, average & percent)
-
Programmable protective relaying functions:
-
kVA (per phase, average & percent)
-
Power factor (per phase & average)
-
Emergency stop pushbutton
-
Generator mounted - rear facing
-
Cat connect
-
Overcurrent (50 / 51)
Cooling System
+
-
-
Package mounted radiator
-
Radiator fan and fan drive
-
Fan and belt guards
-
Coolant drain line with valve
-
Caterpillar extended life coolant (Not included with packages without radiator, installed SF44CTS
-
Coolant level sensors (Not included with packages without radiator)
-
SCAC
Fuel System
+
-
-
Primary fuel filter with integral water separator
-
Secondary fuel filters
-
Flexible fuel lines - shipped loose
-
Fuel priming pump
-
Fuel cooler; not included with packages without radiator
Generators And Attachments
+
-
-
Low voltage:
-
Random wound
-
6 Leads
-
NEMA standard hole pattern
-
High voltage
-
Busbar connections, right side extension box, bottom cable entry
-
NEMA Class H insulation system, Class H temperature rise at 40C ambient
(125C prime / 150C standby)
-
Permanent magnet excitation (PMG)
-
NEMA standard hole pattern
-
Medium voltage:
-
Busbar connections, top center mounted, top cable entry
-
NEMA Class H insulation system, Class H temperature rise at 40C ambient
(125C prime / 150C standby)
-
Winding temperature detectors
-
Form wound
-
3 Phase brushless, Salient pole
-
Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
-
Internal excitation (IE)
Lube System
+
-
-
Lubricating oil
-
Gear type lube oil pump
-
Oil drain lines and valve
-
Fumes disposal
-
Integral lube Oil cooler
-
Oil filter, filler and dipstick
Mounting System
+
-
-
Rubber anti-vibration mounts - shipped loose
Starting / Charging System
+
-
-
Battery disconnect switch
-
Battery and battery rack w/cables
-
45 Amp Charging alternator
-
24 Volt electric starting motor
General
+
-
-
Paint - Caterpillar yellow with high gloss black rails & radiator
-
Flywheel and Flywheel housing-SAE No. 00
-
Right hand servicing
-
SAE standard rotation
Optional Equipment:
Control Panels
+
-
Remote monitoring software
Digital I/O module
EMCP 4.3, EMCP 4.4
Load share module
Generator temperature monitoring & protection
Exhaust System
+
-
Exhaust mufflers
Flanges
Elbows
Flange and exhaust expanders
Mufflers
Y Adapters
Flexible fittings
Generator
+
-
Oversize and premium generators
Permanent magnet excitation (PMG)
Internal excitation (IE)
Anti-condensation heater
Air Inlet System
+
-
Heavy duty air cleaner
Single element filter
Power Termination
+
-
Circuit breakers, UL listed
Circuit breakers, IEC compliant
Cooling System
+
-
Standard installed radiators
Optional installed radicators
Coolant
Water level switch gauges
General
+
-
UL 2200 package
EEC Declaration of Conformity
Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
CSA Certification
Enclosures: Sound attenuated, weather protective
Automatic transfer switches (ATS)
Integral & sub-base fuel tanks
The following options are based on regional and product configuration:
US aid emblem
Integral & sub-base UL listed dual wall fuel tanks
EU Certificate of Conformance (CE)
Generators And Attachments
+
-
1400, 1600, 2700 Frames
Generator conversion from IE to PM
Space heater
RW, IE, 6 Leads, Pitch 0.6667
Low voltage: 380,440 / 480 Volts, 3 Phase, 1800 rpm
Differential current transformers (DCT) 15 kV class
Generator air cleaner
Differential current transformers (DCT) 8.7 kV class
Mounting
+
-
IBC isolators
Rubber anti-vibration mounts
Spring type vibration isolators
Starting/charging
+
-
Air starting motor with control and silencer
Heavy duty starting system
Charging alternator
Oversize batteries
Battery chargers
Jacket water heater
Instrumentation
+
-
Wiring GP W/O cyl sensors
Pyrometer and thermocouples
Lube System
+
-
Lubrication oil in standard sump
Oil drains
Prelube pumps
Oil level regulator
Crankcase Protection
+
-
Explosion relief valves
No crankcase explosion relief valves
Crankcase ventilation system
No explosion relief valves
Mounting System
+
-
IBC vibration isolators
Puck style low efficiency isolators
Spring type vibration isolators
Power Connections
+
-
2000, 2500 Amp, 4 Pole, IECrated Circuit breakers
Cable entry - right side
Grounding groups
Left side power connections
1600 ,2000, 2500, 3000, 4000 Amp, 3 Pole, UL-100% rated Circuit breakers
2000, 2500, 3200 Amp, 3 Pole, IEC rated Circuit breakers
Rear power connections
Neutral ground connections
6 Leads, 6 terminal option
Right side power connections
Center post buss bar
Special Tests / Reports
+
-
Generator test report
PGS Test report @ 0.8 power factor
Standard engine test charge
CSA Certification
Torsional vibration analysis
Generator fuel consumption test
PGS Test report @ 1.0 power factor
IBC seismic Certification
Fuel consumption test
Starting / Charging System
+
-
Air pressure regulator
Batteries, racks and cables:
Air starting motor
35 Amp Battery charger
24 Volt battery set - Dry
Starter cover
10 Amp Battery charger
Engine barring device
Jacket water heaters