+ -Maximum Rating | 13.2 ekW |
Minimum Rating | 12.0 ekW |
Emissions/Fuel Strategy | R96/EUIIIa Equivalent |
Voltage | 110 to 415 Volts |
Frequency | 60 Hz |
Speed | 1800 rpm |
Duty Cycle | Standby, Prime |
Engine Specifications
+ -Engine Model | Cat® C1.5 |
Bore | 3.3in |
Stroke | 3.5in |
Displacement | 91.3in³ |
Compression Ratio | 22.5:1 |
Aspiration | Naturally Aspirated |
Fuel System | Indirect Injection |
Governor Type | Mechanical |
Generator Set Dimensions
+ -Length - Maximum | 55.1in |
Width - Maximum | 24.4in |
Height - Maximum | 41.5in |
Standard Equipment:
Air Inlet System
+ --
Air cleaner; light duty with disposable element
Control Panel
+ --
GCCP 1.3
Cooling System
+ --
Radiator and cooling fan with guards
-
Coolant drain line with valve
-
Fan drive, battery charging alternator drive
-
Caterpillar extended life coolant
Exhaust System
+ --
Stub pipe, gaskets, raincap & SAE exhaust flange for customer use - shipped loose
Fuel System
+ --
Base, formed steel with single wall integral 8-hour fuel tank
-
Standard open set fuel tank/base supplied
Generators And Generator Attachments
+ --
Voltage regulator (single phase sensing)
-
IP23 Protection
-
Segregated low voltage (AC/DC) wiring panel
-
Tower panel, IP22, bottom cable entry
-
Circuit breaker, IEC, 3 pole, mounted in tower panel
-
12 Leads
Governing System
+ --
Mechanical governing system
Lube System
+ --
Oil drain line with valve
-
Lubricating oil
Mounting System
+ --
Captive linear vibration isolators between base and engine-generator
-
includes lifting provisions and termination points for coolant
Starting / Charging System
+ --
12 Volt battery with rack and cables
General
+ --
Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment:
Alternator Options
+ -Coastal insulation protection
Certificates
+ -Global certification for CIS
European upgrade to STD set for CE certificate
Circuit Breakers
+ -Padlockable breaker device
4 Pole Circuit breaker
Control Panel Options
+ -Emergency stop with key
Volt free contacts for genset running
Battery charger
Volt free contacts for common alarm
GCCP 1.3
Cooling System
+ -Coolant heater
Enclosures
+ -Sound attenuated enclosure (GALV)
Single point lift for enclosure
Fuel System
+ -Low fuel level alarm
DEFRA bunded fuel tank
1000 Hr extended service interval
Fuel transfer control
Skidbase for open sets
Base feet
Skidbase for enclosures
Mounting Options
+ -Silencer installation kit
Industrial silencer removal
Battery removal
Special Test And Inspection
+ -PGS Test report @ 1.0 power factor
General
+ -Packing case - canopied set
Packing Case - compact set
Radiator stone guard