+ -Maximum Rating | 13.5 kVA |
Minimum Rating | 10.0 kVA |
Emissions/Fuel Strategy | R96/EUIIIa Equivalent |
Voltage | 110 to 415 Volts |
Frequency | 50 Hz |
Speed | 1500 rpm |
Duty Cycle | Standby, Prime |
Engine Specifications
+ -Engine Model | Cat® C1.5 |
Bore | 3.3in |
Stroke | 3.5in |
Displacement | 91.3in³ |
Compression Ratio | 22.5:1 |
Aspiration | Naturally Aspirated |
Fuel System | Indirect Injection |
Governor Type | Mechanical |
Generator Set Dimensions
+ -Length - Maximum | 55.1in |
Width - Maximum | 24.4in |
Height - Maximum | 41.5in |
Standard Equipment:
Exhaust System
+ --
Stub pipe, gaskets, raincap & SAE exhaust flange for customer use - shipped loose
Control Panel
+ --
GCCP 1.3
Cooling System
+ --
Coolant drain line with valve
-
Caterpillar extended life coolant
-
Radiator and cooling fan with guards
-
Fan drive, battery charging alternator drive
Air Inlet System
+ --
Air cleaner; light duty with disposable element
Fuel System
+ --
Base, formed steel with single wall integral 8-hour fuel tank
-
Standard open set fuel tank/base supplied
Generators And Generator Attachments
+ --
Segregated low voltage (AC/DC) wiring panel
-
Circuit breaker, IEC, 3 pole, mounted in tower panel
-
IP23 Protection
-
12 Leads
-
Tower panel, IP22, bottom cable entry
-
Voltage regulator (single phase sensing)
Governing System
+ --
Mechanical governing system
Lube System
+ --
Lubricating oil
-
Oil drain line with valve
Mounting System
+ --
Captive linear vibration isolators between base and engine-generator
-
includes lifting provisions and termination points for coolant
Starting / Charging System
+ --
12 Volt battery with rack and cables
General
+ --
Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment:
Alternator Options
+ -Coastal insulation protection
Certificates
+ -European upgrade to STD set for CE certificate
Global certification for CIS
Circuit Breakers
+ -4 Pole Circuit breaker
Padlockable breaker device
Control Panel Options
+ -Volt free contacts for common alarm
Volt free contacts for genset running
Emergency stop with key
Battery charger
GCCP 1.3
Cooling System
+ -Coolant heater
Enclosures
+ -Sound attenuated enclosure (GALV)
Single point lift for enclosure
Fuel System
+ -Low fuel level alarm
Mounting Options
+ -Industrial silencer removal
Silencer installation kit
Battery removal
Special Test And Inspection
+ -PGS Test report @ 1.0 power factor
General
+ -Radiator stone guard
Packing Case - compact set
Packing case - canopied set