C175-16 Generator Set
360° Exterior View
At a Glance
|
|
|
|
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
+ -Standby Rating | 3100(no fan)/3000 kVA |
Prime Power Rating | 2825(no fan)/2725 kVA |
Emissions/Fuel Strategy | Low Fuel, Low Emissions |
Voltage | 380 to 11000 Volts |
Frequency | 50 Hz |
Speed | 1500 rpm |
Duty Cycle | Standby, Mission Critical, Prime, Continuous |
Maximum Rating | 3100 kVA |
Minimum Rating | 2500 kVA |
Engine Specifications
+ -Engine Model | C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel |
Bore | 6.89in |
Stroke | 8.66in |
Displacement | 5166.88in³ |
Compression Ratio | 16.7:1 |
Aspiration | Turbo Aftercooled |
Fuel System | Common Rail |
Governor Type | ADEM� A4 |
Generator Set Dimensions
+ -Length - Minimum | 241.6in |
Length - Maximum | 311in |
Width - Minimum | 83in |
Width - Maximum | 108.5in |
Height - Minimum | 87in |
Height - Maximum | 130.2in |
Dry Weight - Genset (minimum) | 42750lb |
Dry Weight - Genset (maximum) | 50750lb |
Standard Equipment:
Air Inlet System
+ --
4 x Single element canister with service indicator(s)
Control Panel
+ --
Cat ECS 100
-
Volts (L-L & L-N)
-
Engine cycle crank
-
Power factor (per phase & average)
-
Overcurrent
-
Communications
-
Emergency stop
-
2 Programmable relay outputs (Form C)
-
6 Programmable digital inputs
-
2 Programmable digital outputs
-
Environmental sealed front face.
-
DC Volts
-
Reverse power
-
Programmable protective relaying functions
-
High coolant temperature
-
Accessory module data link
-
Low coolant level
-
Over/under frequency
-
Amps (per phase & average)
-
True RMS AC metering, 3-phase, +/-2% accuracy
-
Low coolant temperature
-
Reverse reactive power
-
Controls
-
Oil pressure (psi, kPa or bar)
-
Lamp test
-
Coolant temperature
-
Warning/shutdown Indicators:
-
4 Programmable relay outputs (Form A)
-
Alarm acknowledge
-
Generator phase sequence
-
24 Volt DC operation
-
Serial annunciator module data link
-
Customer data link (Modbus RTU)
-
Failure to start (overcrank)
-
Auto/start/stop control.
-
Low oil pressure
-
RPM
-
Text alarm/event descriptions.
-
Digital Indicators
-
Generator mounted - rear facing
-
Emergency stop pushbutton
-
Engine cool-down timer
-
Operating hours
-
Over/under voltage
-
Overspeed
-
Frequency (Hz)
Cooling System
+ --
Radiator group - shipped loose
-
SCAC cooling
-
Coolant Sensors
-
Coolant drain line and valves
-
Fan and belt guards
Exhaust System
+ --
Bolted flange, with bellow for each turbo
-
Dry exhaust manifold
Fuel System
+ --
Filters x 3
-
Secondary/ tertiary fuel filters
-
10 Micron spin On Type
-
4 Micron Spin On Type
-
Primary fuel filter water/fuel water separator
-
Engine mounted filters x 3
Generator And Attachments
+ --
6 Leads
-
IEC platinum stator RTDs
-
Voltage regulator
-
Reactive droop capability
-
3 Phase voltage sensing
-
RFI suppression
-
Min / max exciter limiter
-
exciter diode monitor
-
Form wound
-
Permanent magnet excitation (PMG)
-
NEMA Class H insulation
-
Class H temperature rise at 40C ambient
-
(LV) Busbar connections, top/center mounted, top cable entry
-
3 Phase Brushless
-
Salient pole
-
50 Hz models: IEC standard hole pattern
-
(MV) Busbar connections, right side extension box, bottom cable entry
-
Anti-condensation space heater
-
Class F temperature rise at 40C ambient
-
Right side extension box, bottom cable entry
Governing System
+ --
ADEM A4
-
Redundant shutdown (Overspeed protection through a duplicate speed sensing system)
Lube System
+ --
Gear type lube oil pump
-
Lubricating oil
-
Fumes disposal
-
Integral lube Oil cooler
-
Oil drain lines and valve
-
Oil filter, filler and dipstick
-
Prelube - required with prime, continuous, and standby
Mounting Systems
+ --
Rubber anti-vibration mounts - shipped loose
-
Battery disconnect switch
-
Batteries and battery rack w/cables
-
Dual 24 volt electric starting motors
-
Rails - Engine/generator
Service Instructions
+ --
Two PM inspections
Power Termination
+ --
Busbar
General
+ --
Paint - Caterpillar yellow with high gloss black rails & radiator
-
Right hand servicing
-
Flywheel and flywheel housing-SAE No. 00
-
SAE standard rotation
Optional Equipment:
Air Inlet System
+ -Single element air cleaner
Dual element air cleaner
Air inlet adapters
Air inlet protection
Control Panel
+ -EMCP 4.4
EMCP 4.4 optional harness
Controller and MV&HV power connection locations
Load share module
Controller mounting location - LV / MV
Customer AC-DC connection mounting location - LV/MV
Load share module / auxiliary plate and auxiliary box (LV)
Load share governor
Frame boxes
Automatically selected ground
Controller voltage and current sensing groups
Raise lower switch
Speed adjust
Annunciator modules
Customer interface options
Generator temperature monitoring
Modbus monitoring of packages
E-Stop
Interconnect harness
Generator harness
Cooling System
+ -Package mounted radiator
Remote radiators
Fuel cooler
Exhaust System
+ -Front housing - Standby or mission critical
Front housing - Prime or continuous
Exhaust collectors/manifold
Exhaust support group
Mufflers
Weld flanges
Aftercooler drain
Crankcase Systems
+ -Explosive relief valves
Crankcase ventilation system
Fuel System
+ -Primary fuel filter
Generators And Attachments
+ -Low voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
Medium voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
Low voltage - 1800 and 3000 Frames - 60 Hz, 3 phase, 1800 rpm, FW, PM, No of leads=6, Pitch 0.6667
Space heater kit
Thermostat for space heater
Conversion GP - Top cable entry
Generator air intake
Differential current transformers
Instrumentation
+ -Pyrometer and thermocouples
Lube System
+ -Lube oil heater
Drain group oil pans
Lubricating oil
Electric prelube pumps
Oil filters
Mounting
+ -Rubber anti-vibration mounts
Spring type linear vibration isolators
IBC vibration isolators - Shipped loose
Power Connections
+ -Center post busbarss (LV)
Side/rear mounted busbars (LV)
Harnesses (Breaker)
Cable entry options (LV)
Enclosures - Control packaging (LV)
Power connection covers (LV)
Neutral ground (LV)
1800 Frame generators Circuit breaker
Masterpack breakers
Paralleling circuit breakers
1800 Frame generator side / rear mounted busbars (MV)
Cable entry options (MV)
Neutral ground (MV)
Low voltage connection cable
Masterpack breaker connections
Special Tests / Reports
+ -Generator test report
PGS Test report @ 1.0 power factor
PGS Test report @ 0.8 power factor
Standard genset TVA (Torsional Vibration Analysis) report
Custom generator TVA report
Special test charge - Engine only
Genset fuel consumption test
Standard engine test charge
IBC seismic Certification
OSCOSH1 seismic Certification
Starting / Charging System
+ -24 Volt power distribution box
24 Volt electric starting motor
Air starting motor
Air pressure regulator
Starter location covers
24 Volt battery set - Dry
Heavy duty battery sets with rack
20 Amp Battery chargers
35 Amp Battery chargers
50 Amp Battery chargers
Charging alternators - Dry
Jacket water heaters
Jacket water heater wiring groups
General
+ -Special paint colors
Service tools - Engine barring group
Barring group manual
Engine barring air powered
Control GP - air powered bar group