C18 Generator Set
360° Exterior View
360° Exterior View
At a Glance
|
|
|
|
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
+ -Maximum Rating | 850 kVA |
Minimum Rating | 706 kVA |
Emissions/Fuel Strategy | Low Fuel |
Voltage | 380 to 415 Volts |
Frequency | 50 Hz |
Speed | 1500 |
Duty Cycle | Standby, Prime |
Engine Specifications
+ -Engine Model | C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel |
Bore | 5.71in |
Stroke | 7.2in |
Displacement | 1106.4in³ |
Compression Ratio | 14.5:1 |
Aspiration | Air to Air Aftercooled |
Fuel System | Electronic unit injection |
Governor Type | Adem™A4 |
Generator Set Dimensions
+ -Length - Maximum | 162.4in |
Width - Maximum | 78.3in |
Height - Maximum | 75in |
Standard Equipment:
Air Inlet System
+ --
Single element air cleaner
-
Turbocharger
-
Aftercooler core
-
Light duty air cleaner
Control System
+ --
GCCP 1.3
Cooling
+ --
Coolant drain line with valve
-
Radiator and cooling fan with guard
-
Fan drive, battery charging alternator drive
-
Caterpillar extended life coolant
Exhaust System
+ --
Stainless steel exhaust flex gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Fuel System
+ --
Standard 8 hour open set integral fuel tank
Generator And Attachments
+ --
LC frame generator - IP23 Protection
-
Matched to the performance and output characteristics of Cat engines
-
Segregated low voltage (AC/DC) wiring panel
-
Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
-
Integrated voltage regulator (IVR)
-
Power center, IP22
-
Integrated voltage regulator (IVR)
Governing System
+ --
Cat electronic governor (ADEM A4)
Lube System
+ --
Lubricating oil
-
Oil drain lines with valves
Mounting System
+ --
Captive linear vibration isolators between base and engine-generator.
Starting/charging
+ --
24 Volt battery with rack and cables
General
+ --
Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment:
Air Inlet System
+ -Dual element air cleaner
Circuit Breakers
+ -4 Pole (IEC-100% rated) Circuit breakers - Package mounted
Circuit breaker (IEC) Auxiliary contacts
3 Pole (IEC-100% rated) Circuit breakers - Motorised
Padlockable circuit breaker device
Shunt trip for IEC breaker
Power terminal strip
4 Pole (IEC-100% rated) Circuit breakers - Motorised
3 Pole (IEC-100% rated) Circuit breakers - Package mounted
Control System
+ -Local alarm horn
Protective devices: Earth fault relay - earth leageage Ground fault relay - Overload shutdown via breaker - Low fuel level alarm - Low fuel level shutdown - High fuel level alarm - Fuel level sensor
GCCP 1.4
Remote annunciator module
Oil temperature displays
Local alarm modules
Cooling System
+ -Radiator transition flange
Low coolant temperature alarm
Enclosures
+ -Sound attenuated enclosures (to be available soon)
Exhaust System
+ -8 and 10 inch elbow kits
10, 25, 35 dB end in / end out mufflers
Engine mounted muffler
8 and 10 inch GP flanges
Manifold and turbocharger guards
Fuel System
+ -Integral - Dual wall fuel tank base
Fuel transfer system
Manual fuel transfer pump
Generator And Attachments
+ -Space heaters
A Frame CIP generator
LC frame CIP generator
A Frame oversize generator
Ingress protection
LC frame oversize generators
LC frame generator
Permanent magnet excitation (PMG)
Lube System
+ -Manual sump pump
Starting And Charging
+ -Jacket water heaters
5 Amp Battery charger
Battery disconnect switch
Jacket water heaters