Standard Equipment:
Air Inlet System
+ -Air cleaner; light duty with disposable element
Air Cleaner
Cooling System
+ -Fan drive, battery charging alternator drive
Caterpillar extended life coolant
Coolant drain line with valve
Radiator and cooling fan with guards
Radiator and cooling fan with guards
Coolant drain line with valve
Caterpillar extended life coolant
Fan drive, battery charging alternator drive
Control Panel
+ -EMCP 4.1
EMCP 4 Control panel
Exhaust System
+ -Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Fuel System
+ -Standard open set fuel tank / base supplied base, formed steel with single wall integral 8-hour fuel tank
Standard open set fuel tank / base supplied base, formed steel with single wall integral 8-hour fuel tank
Generator
+ -IP23 protection
Voltage regulator (single phase sensing)
12 leads
Circuit breaker, IEC, 3 pole, mounted in tower panel
Tower panel, IP22, bottom cable entry
Segregated low voltage (AC/DC) wiring panel
12 leads
Governing System
+ -Mechanical and electrical governing system - model dependent
Mechanical and electrical governing system - model dependent
Lube System
+ -Oil drain line with valve
Lubricating oil
Oil drain line with valve
Lubricating oil
Mounting System
+ -Termination points for coolant and lube oil drain lines
Includes lifting provision and drag points
Captive linear vibration isolators between base and engine-generator
Starting/charging System
+ -24V battery with rack and cables
Batteries
24V battery with rack and cables
General
+ -Engine and alternator pre-paint, Caterpillar yellow
Engine and alternator pre-paint, Caterpillar Yellow
Optional Equipment:
Alternator System
+ -Anti-condensation heater
Quadrature droop kit
3 phase sensing
R frame auxilliary winding
LC frame alternator with coastal insulation protection
Permanent magnet
LC frame alternator
R frame auxilliary winding
Circuit Breakers
+ -Circuit Breaker Upgrades - 4 Pole circuit reaker to 250A, 400A and 630 A
Cooling System
+ -Low coolant temp alarm
Coolant heater
Low coolant level shutdown
Control Panel Options
+ -Earth fault (2 wire only)
Control panel heater
Panel mounted audible alarm
Volt free contacts
Voltage adjust potentiometer
Overload shutdown via breaker
Earth leakage (2 wire only)
EMCP 4.2
Emergency stop with key
Speed adjust potentiometer
Battery charger
Enclosures
+ -Rental pack - CAE rental option only
Sound attenuated Level 2 enclosure
Sound attenuated Level 1 (galv)
European Certifications
+ -Upgrade to STD set for CE
Fuel System
+ -Low fuel level shutdown
Compact skidbase for open set
Open set narrow base
Bunded fuel tank
Low fuel level alarm
High fuel level alarm
Skidbase for CALG enclosure sets
Global Certifications
+ -Mounting Options
+ -Electronic governor
External single point lift - enclosure
Silencer installation kit
Industrial silencer
Battery removal
Special Packing/inspectons For Shipment
+ -PGS test report @ 1.0 power factor
PGS test report @ 0.8 power factor
General - Accessories / Miscellaneous
+ -Packing case - canopied set
Packing case - compact set
Stone guards / rad trans flange