C9 | DE275E0 50Hz NON CERTIFIED EMISSIONS
At a Glance
Maximum Rating
275 kVA
|
Minimum Rating
275 kVA
|
Emissions/Fuel Strategy
Non-Certified
|
Voltage
200 to 400 Volts
|
Request a Quote
Overview
Generator Set Specifications
+
-
Maximum Rating |
275 kVA |
Minimum Rating |
275 kVA |
Emissions/Fuel Strategy |
Non-Certified |
Voltage |
200 to 400 Volts |
Frequency |
50 Hz |
Speed |
1500 rpm |
Duty Cycle |
Standby, Prime |
Engine Specifications
+
-
Engine Model |
C9 ATAAC, I-6, 4-Stroke Water-Cooled Diesel |
Bore |
4.41in |
Stroke |
5.87in |
Displacement |
537.01in³ |
Compression Ratio |
16.1:1 |
Aspiration |
Air to Air Aftercooled |
Fuel System |
Hydraulic electronic unit injection |
Governor Type |
Adem™A4 |
Generator Set Dimensions
+
-
Length - Maximum |
157in |
Width - Maximum |
47.5in |
Height - Maximum |
73.5in |
Standard Equipment:
Air Inlet System
+
-
-
Air cleaner, light duty with disposable paper filter
Cooling System
+
-
-
Fan drive, battery charging alternator drive
-
Coolant drain line with valve
-
Radiator and cooling fan with guard
-
Caterpillar extended life coolant
Exhaust System
+
-
-
Stainless steel exhaust flex, gaskets, rain cap & SAE exhaust flange for customer use - shipped loose
Fuel System
+
-
-
Standard open set fuel tank/base supplied
-
Base, formed steel with single wall integral 8-hour fuel tank
Generators And Generator Attachments
+
-
-
IP23 Protection
-
Mandatory option circuit breaker, IEC, 3 pole mounted in power centre
-
Power centre, IP22
-
12 Leads
-
Segregated low voltage (AC/DC) wiring panel
-
Voltage regulator (single phase sensing)
Governing System
+
-
-
Cat electronic governor (ADEM A4)
Lube System
+
-
-
Oil drain valves
-
Lubricating oil
-
Oil cooler
Mounting System
+
-
-
Includes lifting provisions and termination points for coolant and lube oil drain lines
-
Captive linear vibration isolators between base and engine-generator
Starting / Charging System
+
-
-
24V battery with rack and cables
General
+
-
-
Engine and alternator re-paint, Caterpillar yellow
Optional Equipment:
Certifications
+
-
Global Certification for CIS
European Certificate for Conformance
Air Inlet System
+
-
Single element air cleaner
Circuit Breakers
+
-
4 Pole (IEC-100% rated) Circuit breaker upgrades: 400, 630, 800 and 100 amps
Control Panels
+
-
Control panel protective devices: Earth fault relay ; Earth leakage ground fault ; overload shutdown via breaker ; Low fuel level shutdown ; Low fuel level alarm ; Fuel level sensor
Control panel Options: Volt free contacts ; Local alarm horn ; Oil temperature displays
Cooling System
+
-
Radiator duct flange
Low coolant temperature alarm
Enclosures
+
-
Sound attenuated enclosure
High ambient sound attenuated enclosure
Exhaust System
+
-
5 and 6 inch elbow kits
Mufflers - End in/end out; 10 dBA or 25 dBA attenuation
6 inch flange
5 - 6 inch flange adaptor
Fuel System
+
-
Integral dual wall fuel tank base
Generators And Attachments
+
-
Permanent magnet excitation (PMG) generator
Oversize, AREP, CIP generators
Starting / Charging System
+
-
Battery disconnet switch
Jacket water heater
5 Amp single Battery charger