D100 GC Generator Set
360° Exterior View
360° Exterior View
360° Interior View
At a Glance
|
|
|
|
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
+ -Maximum Rating | 100 ekW |
Minimum Rating | 100 ekW |
Emissions/Fuel Strategy | U.S. EPA Cert., Tier 3 |
Voltage | 208 to 600 Volts |
Frequency | 60 Hz |
Speed | 1800 rpm |
Duty Cycle | Standby |
Engine Specifications
+ -Engine Model | C4.4, In-line 4, 4-cycle diesel |
Bore | 4.1in |
Stroke | 5in |
Displacement | 269in³ |
Compression Ratio | 16.7:1 |
Aspiration | Turbocharged |
Fuel System | Common Rail |
Governor Type | Mechanical, ADEM™A4 |
Generator Set Dimensions
+ -Length - Maximum | 82.6in |
Width - Maximum | 43.3in |
Height - Maximum | 52.9in |
Dry Weight - Genset (maximum) | 2222lb |
Standard Equipment:
Air Inlet System
+ --
Air cleaner; light duty with disposable element
-
Air cleaner
Cooling System
+ --
Coolant drain line with valve
-
Radiator and cooling fan with guards
-
Caterpillar extended life coolant
-
Fan drive, battery charging alternator drive
Control Panel
+ --
GCCP 1.2 Control panel
Exhaust System
+ --
Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Fuel System
+ --
Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
Generator
+ --
Circuit breaker, IEC, 3 pole, mounted in tower panel
-
IP23 Protection
-
Tower panel, IP22, bottom cable entry
-
12 Leads
-
Voltage regulator (single phase sensing)
-
Segregated low voltage (AC/DC) wiring panel
Governing System
+ --
Mechanical and electrical governing system - model dependent
Lube System
+ --
Lubricating oil
-
Oil drain line with valve
Mounting System
+ --
Termination points for coolant and lube oil drain lines
-
Captive linear vibration isolators between base and engine-generator
-
Includes lifting provision and drag points
Starting/charging System
+ --
Batteries
-
24V battery with rack and cables
General
+ --
Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment:
Alternator System
+ -Anti-condensation heater
3 phase sensing
Permanent magnet excitation (PMG)
R Frame auxilliary winding
Quadrature droop kit
Circuit Breakers
+ -Circuit breaker upgrades - 4 Pole circuit reaker to 250A, 400A and 630 A
Cooling System
+ -Coolant heater
Low coolant temperature alarm
Low coolant level shutdown
Control Panel Options
+ -Earth fault (2 wire only)
Control panel heater
GCCP 1.2 Control panel
Volt free contacts
Emergency stop with key
Voltage adjust potentiometer
Overload shutdown via breaker
Panel mounted audible alarm
Battery charger
Earth leakage (2 wire only)
Speed adjust potentiometer
Enclosures
+ -Sound attenuated Level 2 enclosure
Fuel System
+ -Low fuel level alarm
Bunded fuel tank
Low fuel level shutdown
High fuel level alarm
Mounting Options
+ -Battery removal
Electronic governor
Industrial silencer
External single point lift - enclosure
Silencer installation kit
Special Packing/inspectons For Shipment
+ -PGS Test report @ 0.8 power factor
PGS Test report @ 1.0 power factor
General - Accessories / Miscellaneous
+ -Packing case - canopied set
Packing case - compact set
Stone guards/rad trans flange