Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
+ -Maximum Rating | 150 ekW |
Minimum Rating | 150 ekW |
Emissions/Fuel Strategy | U.S. EPA Cert., Tier 3 |
Voltage | 208 to 600 Volts |
Frequency | 60 Hz |
Speed | 1800 rpm |
Duty Cycle | Standby |
Engine Specifications
+ -Engine Model | C7.1 I-6, 4-Cycle Diesel |
Bore | 4.1in |
Stroke | 5.31in |
Displacement | 428in³ |
Compression Ratio | 16.7:1 |
Aspiration | Turbocharged, Air to Air Aftercooled |
Fuel System | Electronic, Common Rail |
Governor Type | ADEM™A4 |
Generator Set Dimensions
+ -Length - Maximum | 103.7in |
Width - Maximum | 51.2in |
Height - Maximum | 52.2in |
Dry Weight - Genset (maximum) | 3443lb |
Standard Equipment:
Air Inlet System
+ --
Air cleaner; light duty with disposable element
Control Panels
+ --
GCCP 1.2 Control panel
Cooling System
+ --
Fan drive, battery charging alternator drive
-
Radiator and cooling fan with guards
-
Coolant drain line with valves
-
Caterpillar extended life coolant
Generator And Generator Attachments
+ --
12 Leads
-
Segregated low voltage (AC/DC) wiring panel
-
IP23 Protection
-
Tower panel, IP22, bottom cable entry
-
Voltage regulator (single phase sensing)
-
Circuit breaker, IEC, 3 pole, mounted in tower panel
Exhaust System
+ --
Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Fuel System
+ --
Standard open set fuel tank/base supplied
-
Base, formed steel with single wall integral 24-hour fuel tank
Lube System
+ --
Lubricating oil
-
Oil drain line with valve
Mounting System
+ --
Termination points for coolant and lube oil drain lines
-
Captive linear vibration isolators between base and engine-generator
-
Includes lifting provision and drag points
Starting / Charging System
+ --
24V battery with rack and cables
Governing System
+ --
Mechanical and electrical governing system - model dependent
General
+ --
Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment:
Alternator System
+ -R Frame auxiliary winding: R2273L4 SE aux alt 07, aux alt 08 and aux alt 10
Anti-condensation heater
3 Phase sensing
Quatrature droop king
Alternator removal
Permanent magnet excitation (PMG)
Circuit Breakers
+ -Padlockable breaker device
4 Pole 250A, 400A and 630A Circuit breakers
Control Panel Options
+ -Battery charger
Panel mounted audible alarm
Emergency stop with key
Speed adjust potentiometer
Control panel heater
Earth leakage (2 wire only)
Earth fault (2 wire only)
Speed adjust contacts
Overload shutdown via breaker
Volt free contacts
Control System
+ -Volt free contacts for common alarm
Static battery charger
Volt free contacts for generator set running
Cooling System
+ -Coolant heater
Low coolant level shutdown
Low coolant temperature
Enclosures
+ -Sound attenuated level 2 enclosure
Mounting Options
+ -Electronic governor
Residential silencer
Industrial silencer removal
Silencer installation kit
Battery removal
Fuel Systems
+ -High fuel level alarm
Skidbase for CALG enclosure sets
Compact skidbase for open sets
Open set narrow tankbase
Low fuel level alarm
DEFRA bunded fuel tank
Low fuel level shutdown
Test Reports
+ -PGS Test report @ 1.0 power factor
PGS Test report @ 0.8 power factor
General
+ -Stone guards/radiator trans flange
Power Termination
+ -Circuit breaker, IEC, 4 pole
Accessories / Miscellaneous
+ -Packing case - canopied set
Packing case - compact set