D200 GC Generator Set
360° Exterior View
360° Exterior View
360° Interior View
At a Glance
|
|
|
|
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
+ -Maximum Rating | 200 ekW |
Minimum Rating | 200 ekW |
Emissions/Fuel Strategy | U.S. EPA Cert., Tier 3 |
Voltage | 208 to 600 Volts |
Frequency | 60 Hz |
Speed | 1800 rpm |
Duty Cycle | Standby |
Engine Specifications
+ -Engine Model | C7.1 I-6, 4-Cycle Diesel |
Bore | 4.1in |
Stroke | 5.31in |
Displacement | 428in³ |
Compression Ratio | 16.7:1 |
Aspiration | Turbocharged, Air to Air Aftercooled |
Fuel System | Electronic, Common Rail |
Governor Type | ADEM™A4 |
Generator Set Dimensions
+ -Length - Maximum | 103.7in |
Width - Maximum | 51.2in |
Height - Maximum | 58.7in |
Dry Weight - Genset (maximum) | 3917lb |
Standard Equipment:
Air Inlet System
+ --
Air cleaner; light duty with disposable element
Control Panels
+ --
GCCP 1.2 Control panel
Cooling System
+ --
Coolant drain line with valves
-
Radiator and cooling fan with guards
-
Caterpillar extended life coolant
-
Fan drive, battery charging alternator drive
Generator And Generator Attachments
+ --
Segregated low voltage (AC/DC) wiring panel
-
Voltage regulator (single phase sensing)
-
Circuit breaker, IEC, 3 pole, mounted in tower panel
-
Tower panel, IP22, bottom cable entry
-
12 Leads
-
IP23 Protection
Exhaust System
+ --
Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Fuel System
+ --
Standard open set fuel tank/base supplied
-
Base, formed steel with single wall integral 24-hour fuel tank
Lube System
+ --
Oil drain line with valve
-
Lubricating oil
Mounting System
+ --
Captive linear vibration isolators between base and engine-generator
-
Includes lifting provision and drag points
-
Termination points for coolant and lube oil drain lines
Starting / Charging System
+ --
24V battery with rack and cables
Governing System
+ --
Mechanical and electrical governing system - model dependent
General
+ --
Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment:
Alternator System
+ -Quatrature droop king
Permanent magnet excitation (PMG)
R Frame auxiliary winding: R2273L4 SE aux alt 07, aux alt 08 and aux alt 10
Alternator removal
Anti-condensation heater
3 Phase sensing
Optional LC Frame alternator with coastal insulation protection
Circuit Breakers
+ -Padlockable breaker device
4 Pole 250A, 400A and 630A Circuit breakers
Control Panel Options
+ -Earth leakage (2 wire only)
Panel mounted audible alarm
Speed adjust potentiometer
Overload shutdown via breaker
Emergency stop with key
Earth fault (2 wire only)
Control panel heater
Battery charger
Speed adjust contacts
Volt free contacts
Control System
+ -Volt free contacts for generator set running
GCCP 1.2
Volt free contacts for common alarm
Static battery charger
Cooling System
+ -Low coolant temperature
Coolant heater
Low coolant level shutdown
Enclosures
+ -Sound attenuated level 2 enclosure
Mounting Options
+ -Silencer installation kit
Battery removal
Electronic governor
Industrial silencer removal
Residential silencer
Fuel Systems
+ -Open set narrow tankbase
Low fuel level shutdown
Low fuel level alarm
Compact skidbase for open sets
DEFRA bunded fuel tank
High fuel level alarm
Skidbase for CALG enclosure sets
Test Reports
+ -PGS Test report @ 1.0 power factor
PGS Test report @ 0.8 power factor
General
+ -Stone guards/radiator trans flange
Global Certifications
+ -Certification for CIS
Power Termination
+ -Circuit breaker, IEC, 4 pole
Accessories / Miscellaneous
+ -Packing case - canopied set
Packing case - compact set