Standard Equipment:
Air Inlet System
+ -Air Cleaner; light duty with disposable element
Air Cleaner; light duty with disposable element
Control Panels
+ -GCCP 1.2 control panel
GCCP 1.2
Cooling System
+ -Radiator and cooling fan with guards
Radiator and cooling fan with guards
Coolant drain line with valves
Fan drive, battery charging alternator drive
Caterpillar extended life coolant
Generator And Generator Attachments
+ -Circuit breaker, IEC, 3 pole, mounted in tower panel
12 leads
12 leads
IP23 protection
IP23 protection
Segregated low voltage (AC/DC) wiring panel
Tower panel, IP22, bottom cable entry
Tower panel, IP22, bottom cable entry
Circuit breaker, IEC, 3 pole, mounted in tower panel
Voltage regulator (single phase sensing)
Exhaust System
+ -Stub pipe, gaskets, raincap and SAE exhaust flange for customer use; shipped loose
Fuel System
+ -Base, formed steel with single wall integral 8-hour fuel tank
Standard open set fuel tank / base supplied
Base, formed steel with single wall integral 8-hour fuel tank
Standard open set fuel tank / base supplied
Lube System
+ -Lubricating oil
Oil drain line with valve
Lubricating oil
Oil drain line with valve
Mounting System
+ -Termination points for coolant and lube oil drain lines
Captive linear vibration isolators between base and engine-generator
Includes lifting provision and drag points
Includes lifting provision and drag points
Captive linear vibration isolators between base and engine-generator
Starting / Charging System
+ -24V battery with rack and cables
Governing System
+ -Mechanical and electrical governing system - model dependent
Mechanical and electrical governing system - model dependent
General
+ -Engine and alternator pre-paint, Caterpillar Yellow
Engine and alternator pre-paint, Caterpillar Yellow
Optional Equipment:
Alternator System
+ -R frame auxiliary winding: R2273L4 SE aux alt 07, aux alt 08 and aux alt 10
Permanent magnet
Quatrature droop king
Anti-condensation heater
Alternator removal
Optional LC frame alternator with coastal insulation protection
3 Phase sensing
Circuit Breakers
+ -4 Pole 250A, 400A and 630A Circuit Breakers
Padlockable breaker device
Control Panel Options
+ -Battery charger
Emergency stop with key
Earth fault (2 wire only)
Overload shutdown via breaker
Earth leakage (2 wire only)
Volt free contacts
Control panel heater
Earth fault (2 wire only)
Speed adjust contacts
Speed adjust contacts
Panel mounted audible alarm
Speed adjust potentiometer
Earth leakage (2 wire only)
Battery charger
Control System
+ -Control panel heater
Volt free contacts for common alarm
GCCP 1.2
Static battery charger
Volt free contacts for generator set running
Cooling System
+ -Coolant heater
Low coolant level shutdown
Low coolant level shutdown
Low coolant temperature
Enclosures
+ -Sound attenuated level 2 enclosure
Mounting Options
+ -Industrial silencer removal
Electronic governor
Silencer installation kit
Electronic governor
Residential silencer
Battery removal
Fuel Systems
+ -DEFRA bunded fuel tank
Low fuel level alarm
Skidbase for CALG enclosure sets
Low fuel level alarm
Open set narrow tankbase
Compact skidbase for open sets
Low fuel level shutdown
Low fuel level shutdown
Compact skidbase for open sets
High fuel level alarm
Test Reports
+ -PGS test report @ 1.0 power factor
PGS test report @ 0.8 power factor
General
+ -Stone guards / radiator trans flange
Global Certifications
+ -Certification for CIS
Certification for CIS
Power Termination
+ -Circuit breaker, IEC, 4 pole
Accessories / Miscellaneous
+ -Packing case - compact set
Packing case - canopied set