D300 GC (60 Hz) Generator Set
At a Glance
Maximum Rating
300 ekW
|
Minimum Rating
300 ekW
|
Emissions/Fuel Strategy
EPA Stationary Emergency
|
Voltage
208 to 600 Volts
|
Request a Quote
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
+
-
Maximum Rating |
300 ekW |
Minimum Rating |
300 ekW |
Emissions/Fuel Strategy |
EPA Stationary Emergency |
Voltage |
208 to 600 Volts |
Frequency |
60 Hz |
Speed |
1800 rpm |
Duty Cycle |
Standby |
Engine Specifications
+
-
Engine Model |
Cat® C9 In-line 6, 4-cycle diesel |
Bore |
4.4in |
Stroke |
5.9in |
Displacement |
538in³ |
Compression Ratio |
16.3:1 |
Aspiration |
Turbocharged Air-to-Air Aftercooled |
Fuel System |
HEUI |
Governor Type |
Adem™A4 |
Generator Set Dimensions
+
-
Length - Maximum |
155.5in |
Width - Minimum |
56.3in |
Width - Maximum |
56.7in |
Height - Minimum |
67.2in |
Height - Maximum |
86.7in |
Dry Weight - Genset (minimum) |
5518.2lb |
Dry Weight - Genset (maximum) |
6929.1lb |
Standard Equipment:
Air Inlet System
+
-
-
Aftercooler core
-
Turbocharger
-
Air cleaner - Non canister, disposable
Cooling System
+
-
-
Jacket water pump, gear driven, centrifugal
-
Thermostats and housing
-
Coolant drain valve
-
Radiator sight gauge
-
Blower fan and fan drive with guards
-
Radiator, package mounted
Fuel System
+
-
-
Integral tank base, 24 hours, UL142
-
Fuel priming pump
-
Engine fuel transfer pump
-
Primary fuel filter w/integral water separator and secondary filter, spin on
Generator Set
+
-
-
Complete system designed & built at ISO 9001:2000 certified facilities
-
All protective devices and control functions simulated and checked
-
Factory tested to design specifications at full load conditions
Generators And Generator Attachments
+
-
-
IP23 Protection
-
12 Leads
-
Insulation system, Class H
-
Standard winding protection for non-harsh environments with relative humidity ? 95%
-
Voltage regulator (single phase sensing)
-
Easy access to AVR and terminals
-
Terminal box, IP22 RHS facing, bottom cable entry
-
Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
Governing System
+
-
-
Cat electronic governor (ADEM A4)
Lube System
+
-
-
Shallow oil pan
-
Oil cooler
-
Fumes disposal to front of radiator
-
Oil drain with valve
-
Oil filler and dipstick
-
Oil filter, spin on
-
Lubricating oil, CK-4 (10W-30)
Mounting System
+
-
-
Captive linear vibration isolators between base and engine-generator
-
Includes lifting provisions and termination points for coolant and lube oil drain lines
Protection
+
-
-
Safety shutoff - High water temperature
-
Safety shutoff - Low oil pressure
-
Safety shutoff - Overspeed
Starting/charging System
+
-
-
24-volt electric starting motor
-
24V, 45 Amp Charging alternator
General
+
-
-
Lifting eyes
-
Vibration damper
-
Parts book
Optional Equipment:
Air Inlet System
+
-
Air cleaner (Non canister disposable)
Bases, Mounting & Fuel Tanks
+
-
Integral tank base, 24 hours, UL142
Audio & visual fuel alarm (@90% fuel level)
Wide Base - Skid
Fuel tank pill pipe & lockable cap
Circuit Breaker
+
-
400A LSI
600A LSI
1200A LSI
800A LS/I
Auxiliary contacts
600A LS/I
1200A LS/I
400A LS/I
800A LSI
Control System
+
-
Audible alarm Gp
16 -light NFPA 99/110 Annunciator
Twist release, Red button emergency stop
Ground fault relay
100A Load center
Product link remote monitoring hardware
20A GFCI (Ground Fault Circuit Interrupter)
Volt free contacts
Enclosures
+
-
Sound attenuated Level 2 enclosure (White)
AC & DC Source lights
E-Stop
Exhaust System
+
-
6" Muffler - 25 dBA attenuation
Manifold and turbocharger guards
Flexible exhaust connection
Generator
+
-
Space heater
Permanent magnet excitation (PMG) generator
Starting System
+
-
Battery charger (UL Certified)
Jacket water heater
Standard battery set: 1000 CCA, 90 amp/hr.
General
+
-
CSA Certification
Extended Service Coverage
UL2200 Certification
Generator test report