DG350-2 (Single-phase)
At a Glance
|
|
|
|
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
+ -Frequency | 60 Hz |
Natural Gas Rating | 350 eKW |
Emissions/Fuel Strategy | U.S. EPA Certified for Non-Emergency Application |
Fuel Type | Natural Gas |
Displacement | 1336.42in³ |
Speed | 1800 rpm |
Engine Specifications
+ -Engine Model | G21.9L Spark-Ignited |
Compression Ratio | 10.1 |
Fuel System | Carburetor, Down Draft |
Governor Type | Electronic |
Aspiration | Turbocharged - Aftercooled |
Bore | 5.03in |
Stroke | 5.6in |
Generator Set Dimensions
+ -Length | 154.4in |
Width | 71in |
Height | 67.6in |
Weight | 8274lb |
Standard Equipment:
Cooling
+ --
Closed coolant recovery system
-
50/50 Ethylene glycol antifreeze
-
Factory-installed radiator
-
Radiator and cooling fan complete with protective guards
-
Standard ambient temperatures up to 50°C (122°F)
Air Inlet
+ --
Single element air filter
Fuel
+ --
Primary and secondary fuel shut-off
-
Fuel pressure test po
-
Low fuel pressure switch
-
Dual lock off valves
-
NPT connection
-
Natural Gas or LP Vapor
Exhaust
+ --
Exhaust outlet with 3” pipe
Generator
+ --
Full load capacity alternator
-
Class H insulation material
-
Permanent magnet excitation
-
Permanent magnet excitation
-
Integrated Voltage Regulator
-
Class H insulation material
-
IP23 Protection
-
Matched to the performance and output characteristics of Cat engines
-
Full load capacity alternator
Controls
+ --
EMCP 4.2 Series generator set controller
Mounting
+ --
Vibration isolaton (puck type)
-
Rubber vibration isolators
Electric Starting And/or Prelube
+ --
Engine electrical system
-
Battery cables
-
Solenoid activated starter motor
-
Solenoid activated starter motor
Electric Power - Package Serial Number Prefix
+ --
Battery charging alternator
Governor
+ --
Electronic governor (non adjustable)
Control Panel
+ --
EMCP 4.2 Series generator set controller
Starting/charging
+ --
12 volt starting motor
-
Batteries with rack and cables
Optional Equipment:
Starting/charging
+ -Charging alternator
Battery charger – UL Listed 10 amp
Battery heater
Jacket water heater
General
+ -UL 2200 package
CSA Certification
Suitable for Use as Service Equipment (SUSE)
Automatic transfer switches (ATS)
Enclosures: sound attenuated, weather protective
Generator
+ -Anti-condensation heater
Thermal magnetic or electronic trip MCCBs
Shunt trip and auxiliary contact breaker
Excitation: [ ] Permanent Magnet Excited (PM)
Oversize and premium generators
Anti-condensation heater